首页> 外文期刊>International Transactions on Electrical Energy Systems >A hybrid islanding detection technique for inverter‐based distributed generator units
【24h】

A hybrid islanding detection technique for inverter‐based distributed generator units

机译:基于逆变器的分布式发电机组的混合孤岛检测技术

获取原文
获取原文并翻译 | 示例
           

摘要

Due to high importance of islanding detection as an essential protection requirement, especially for the distributed generation (DG), a new approach to islanding detection is developed in the present paper. The method is based on a mixture of both active and passive algorithms, which uses voltage phase angle (VPA) and voltage unbalance (VU). The suggested method presents a combination of benefits of each individual passive/active method, and therefore it is useful to appropriately detect islanding situation in a wide range of scenarios. The use of the suggested method results in smaller nondetection zone (NDZ), faster response, and improved power quality. In order to illustrate the effectiveness of this approach, simulation results are provided under different conditions, showing that the suggested algorithm can reach the required islanding protection requirements. In addition, the performance of the proposed method and some other methods are compared by the presence of a variety of transient faults and insignificant power mismatch.
机译:由于孤岛检测作为一项重要的保护要求,特别是对于分布式发电(DG),具有很高的重要性,因此,本文提出了一种新的孤岛检测方法。该方法基于主动和被动算法的混合,使用电压相角(VPA)和电压不平衡(VU)。建议的方法结合了每种被动/主动方法的优点,因此在多种情况下正确检测孤岛情况很有用。使用建议的方法可实现更小的非检测区(NDZ),更快的响应速度和更高的电能质量。为了说明该方法的有效性,在不同条件下提供了仿真结果,表明所建议的算法可以达到所需的孤岛保护要求。此外,通过各种瞬态故障和不明显的功率失配来比较所提出的方法和其他方法的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号