首页> 外文期刊>International journal of steel structures >Finite Element Investigation of Shear Capacity of Locally Corroded End Panel of Steel Plate Girder
【24h】

Finite Element Investigation of Shear Capacity of Locally Corroded End Panel of Steel Plate Girder

机译:钢板梁局部腐蚀端板抗剪承载力的有限元研究

获取原文
获取原文并翻译 | 示例
           

摘要

This study discusses the effect of local corrosion damages nearby the bearing region including the bearing stiffener and adjacent web damage on the ultimate shear and post-buckling strength of steel plate girder bridges. A computer package ABAQUS is utilized for the verification and extension of the numerical study. Various corrosion damage cases, specifically the bearing stiffener are studied considering different damage thickness and damage heights. The study concludes that local damage on bearing stiffener damage is more fatal than the local web damage for the shear resistance of the plate girder. Further, some empirical relationships are also derived to assess the residual shear capacity of the locally corroded plate girder at the bearing region.
机译:这项研究讨论了轴承区域附近的局部腐蚀损伤(包括轴承加劲肋和相邻腹板的损伤)对钢板梁桥的极限抗剪强度和屈曲后强度的影响。计算机软件包ABAQUS用于数值研究的验证和扩展。考虑了不同的损伤厚度和损伤高度,研究了各种腐蚀损伤情况,特别是轴承加强筋。研究得出的结论是:对于板梁的抗剪强度,局部受力对支撑加劲肋的破坏要比局部腹板的破坏更为致命。此外,还得出了一些经验关系,以评估局部腐蚀的板梁在承载区域的残余剪切能力。