The computational analysis method of a hybrid structure composed of cables, bars and beams and its preliminary mechanical properties are presented in this paper. At first, based on the local analysis method, the distribution and magnitude of pre-stress of this hybrid structure is analysed using the optimal theory. Then, the optimal pre-stress distribution is obtained. The outmost ring of cable and bar has the largest pre-stress compared with the middle one and the inner one. Second, nonlinear static analysis is carried out with induction of the pre-stress in beams as self-equilibrated initial internal force. The tensegric system and pre-stress in the whole structure could not reduce the deflection dramatically. However, the pre-stress can significantly affects the distribution of the axial forces in beams. Also, linear and nonlinear dynamic analysis is conducted by taking account of the pre-stress of beams as self-equilibrated initial internal force. With the decrease of the stiffness of the upper reticulated structure the effect of pre-stress on natural frequencies of the whole structure becomes larger. The fluctuation of the internal force in the cables and bars is not very large under vertical frequently meeting earthquake load (not over 7%) and smaller under horizontal frequently meeting earthquake load. At last, buckling analysis is carried out. Comparing to single-layer reticulated shell, this type of hybrid structures has much higher limit load capacity ability.
机译:本文提出了一种由索,杆,梁组成的混合结构的计算分析方法及其初步的力学性能。首先,基于局部分析方法,利用最优理论分析了该混合结构的预应力分布和大小。然后,获得最佳的预应力分布。与中间和内部相比,电缆和钢筋的最外面的环具有最大的预应力。其次,通过将梁中的预应力感应为自平衡初始内力来进行非线性静力分析。张拉系统和整个结构中的预应力不能显着减小挠度。但是,预应力会显着影响梁中轴向力的分布。而且,通过考虑梁的预应力作为自平衡初始内力来进行线性和非线性动力分析。随着上部网状结构刚度的降低,预应力对整个结构固有频率的影响变得更大。在经常遇到地震荷载的垂直方向上,电缆和钢筋的内力波动不是很大(不超过7%),而在经常遇到地震荷载的水平方向上的波动较小。最后进行屈曲分析。与单层网壳相比,这种混合结构具有更高的极限承载能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号