A closed‐form solution for power balance equation of electric arc furnace (EAF) isrnproposed in this paper based on field measurements of the instantaneous furnacernvoltage and current. The method is developed based on an analytical solution ofrnpower balance equation in general case. The closed‐form solution is dependent onrnthe EAF parameters, which should be found by parameter identification procedurerncarrying out by minimization of an appropriate objective function. The minimizationrnis performed by means of a calculus‐based optimization method, namely, interiorpointrnmethod. The validity of the proposed method is verified by comparing itsrnresults with those of the field measurements. The results show quite satisfactoryrncorrelation between the proposed method and the actual EAF operation.
机译:本文基于瞬时炉电压和电流的现场测量结果,提出了一种电弧炉功率平衡方程的闭式解。该方法是基于一般情况下功率平衡方程的解析解而开发的。封闭形式的解决方案取决于EAF参数,应通过最小化适当的目标函数来执行的参数识别过程来找到EAF参数。最小化是通过基于演算的优化方法(即interiorpoint方法)执行的。通过将其结果与现场测量结果进行比较,验证了所提方法的有效性。结果表明,所提方法与实际电炉运行之间具有令人满意的相关性。