首页> 外文期刊>International journal of power electronics >Improving load regulation in current mode control through inductor current filtering
【24h】

Improving load regulation in current mode control through inductor current filtering

机译:通过电感电流滤波改善电流模式控制中的负载调节

获取原文
获取原文并翻译 | 示例
           

摘要

Current mode control (CMC) though offers improved line regulation, phase margin and high bandwidth suffers from high output impedance. Although load regulation can be improved by incorporating an integral gain, it reduces the phase margin and increases the overshoot. The objective of this paper is to achieve improved output impedance without using an integral controller. Incorporating a high pass filter in series with the current sensor in CMC, the closed loop DC gain of a CCM buck converter is shown to be almost independent of the load resistance, thus improving load regulation using a proportional controller only. Improved features of CMC are also retained. Following VMC modeling approach, we develop a method to obtain the small signal model of the proposed scheme, and extended to CMC with an accurate low frequency characterisation. The proposed scheme is implemented on a buck converter, and the theoretical results are validated by experiments.
机译:电流模式控制(CMC)虽然提供了改进的线路调节,相位裕度和高带宽,但其输出阻抗很高。尽管可以通过合并积分增益来改善负载调节,但它会减小相位裕量并增加过冲。本文的目的是在不使用集成控制器的情况下提高输出阻抗。将高通滤波器与CMC中的电流传感器串联在一起,可以看出CCM降压转换器的闭环DC增益几乎与负载电阻无关,因此仅使用比例控制器即可改善负载调节。还保留了CMC的改进功能。遵循VMC建模方法,我们开发了一种方法来获得所提出方案的小信号模型,并扩展到具有准确的低频特性的CMC。提出的方案在降压转换器上实现,并通过实验验证了理论结果。