Estimation of sensor response characteristics is necessary to satisfy requirements on allowable response time for nuclear power plants. The methodology currently used includes direct and indirect measurements, each of them having its advantages and disadvantages. The objective of this work is to compare the time response measurements of temperature and pressure sensors which the Brazilian Angra 1 nuclear power plant obtained using direct and indirect methodologies. Direct methods give more precise results but need special equipment to be carried out and they interfere with the reactor operation. Indirect methodology is most practical to perform; it does not interfere with the reactor operation because the sensors do not have to be out of operation. On the other hand, since the parameter identification depends on the noise characteristics, there are cases where indirect methodology is not suitable to predict time response.
机译:传感器响应特性的估计对于满足核电站允许响应时间的要求是必要的。当前使用的方法包括直接和间接测量,每种方法都有其优点和缺点。这项工作的目的是比较巴西Angra 1核电站使用直接和间接方法获得的温度和压力传感器的时间响应测量值。直接方法可提供更精确的结果,但需要使用特殊的设备并且干扰了反应堆的运行。间接方法是最实用的方法。它不会干扰反应堆的运行,因为传感器不必停止运行。另一方面,由于参数识别取决于噪声特性,因此在某些情况下间接方法不适用于预测时间响应。