首页> 外文期刊>International journal of nuclear desalination >Experimental study of falling film evaporation on horizontal tube bundle for a desalination unit
【24h】

Experimental study of falling film evaporation on horizontal tube bundle for a desalination unit

机译:海水淡化装置水平管束降膜蒸发实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

The objective of the present research is to experimentally study the effect of the tube configuration and also the effect of the operating conditions on the evaporation rate of the horizontal tube bundle. An experimental test loop was installed and the water spray on a horizontal tube bundle with three nozzles of fan-jet flat nozzle type. The results show that evaporation rate and Nusselt number are increased by increasing the tube surface temperature, increasing the tube's outer diameter, decreasing the evaporation pressure and decreasing the inlet liquid sub-cooling. The falling distance has little influence on the evaporation rate. Constructing water collector around the bottom-heated tubes enhances the evaporation rate. Also, increasing the gap between the water collector and the outer tube surface, from 0.0 to 4.0 mm, results in increasing the evaporation rate. An empirical correlation has been deduced describing the relation between the average heat transfer coefficient and the affecting operating parameters.
机译:本研究的目的是通过实验研究管结构的影响以及操作条件对水平管束蒸发速率的影响。安装了一个实验测试回路,将水喷洒在带有三个扇形喷射扁平喷嘴类型的水平管束上。结果表明,通过增加管表面温度,增加管的外径,降低蒸发压力和减少入口液体过冷度,可以提高蒸发速率和Nusselt数。下降距离对蒸发速率影响很小。在底部加热管周围构造集水器可提高蒸发速率。同样,将集水器和外管表面之间的间隙从0.0毫米增加到4.0毫米,会导致蒸发速率增加。得出了经验相关性,描述了平均传热系数与影响的运行参数之间的关系。