首页> 外文期刊>International Journal of Heat and Mass Transfer >Experimental data and model for heat transfer, in liquid falling film flow on shell-side, for spiral-wound LNG heat exchanger
【24h】

Experimental data and model for heat transfer, in liquid falling film flow on shell-side, for spiral-wound LNG heat exchanger

机译:螺旋缠绕式LNG换热器在壳侧液膜流中传热的实验数据和模型

获取原文
获取原文并翻译 | 示例
           

摘要

A test plant has been constructed for measurements of local heat-transfer coefficients and frictional pressure drops on the shell-side of spiral-wound LNG heat exchangers. Measurements have been performed with single-phase vapor flow, liquid film flow and two-phase shear flow. This paper focuses on the measurements and the results from the liquid falling film flow experiments. One hundred and seventy-one liquid falling film heat-transfer measurements have been performed at a film Renumber range of 500-8000 with ethane, propane, methane/ethane mixture, ethane/propane mixtures and ethane/ n-butane mixture as test fluids.
机译:在螺旋缠绕式LNG换热器的壳侧,已经建造了一个测试装置,用于测量局部传热系数和摩擦压降。用单相蒸气流,液膜流和两相剪切流进行了测量。本文着重于液体降膜流动实验的测量和结果。在乙烷,丙烷,甲烷/乙烷混合物,乙烷/丙烷混合物和乙烷/正丁烷混合物作为测试液的情况下,在500-8000的膜重数范围内执行了171个降膜传热测试。