Effects of the upper inflow area on pool boiling heat transfer in a vertical annulus

机译:上环流面积对垂直环空池沸腾传热的影响

获取原文
获取原文并翻译 | 示例
       

摘要

The upper inflow area has been changed to identify the effects of it on pool boiling heat transfer in a vertical annulus. Both bottom inflow conditions of the open and the closed are considered for the study. For the test, a heated tube of 25.4 mm diameter and the water at atmospheric pressure have been used. The ratios of the gaps have been varied from 0.18 to 1. Effects of the inflow area on heat transfer become evident as the heat flux increases and the gap ratio decreases. If the gap ratio is smaller than 0.51 and the heat flux is higher than 60 kW/m~2, a noticeable decrease in heat transfer is observed. The major cause for the tendency is attributed to the formation of a lumped bubble around the upper regions of the annulus.
机译:上部流入区域已更改,以识别其对垂直环空中池沸腾传热的影响。研究中考虑了开放式和封闭式的底部流入条件。为了进行测试,使用了直径为25.4 mm的加热管和大气压下的水。间隙的比率已从0.18更改为1。随着热通量的增加和间隙比率的减小,流入面积对传热的影响变得明显。如果间隙比小于0.51,并且热通量大于60 kW / m〜2,则观察到传热明显降低。造成这种趋势的主要原因是由于在环的上部区域周围形成了块状气泡。