Optimum ventilation based on the ventilation effectiveness for temperature and CO_2 distribution in ventilated cavities

机译:根据通风效率对通风腔中温度和CO_2进行分配以实现最佳通风

获取原文
获取原文并翻译 | 示例
       

摘要

Numerical results obtained from the analysis of the conjugated heat and mass transfer of an Air-Carbon Dioxide mixture (CO_2) inside a ventilated cavity in turbulent flow regime are presented. Different configurations of the cavity were analyzed regarding the location of the mixture outlet gap in order to study the thermal behavior and the air quality inside the cavity and to determine a good ventilation configuration. Four different values for the CO_2 contaminant source (500,1000, 2000,3000 ppm) are considered. The air inlet gap is located on the lower side of the right vertical wall of the cavity. The inlet air velocity is a function of the Reynolds number (5 × 10~2 ≤ Re≤ 4 × 10~4). The location for the mixture outlet gap was considered in four different positions: Case A, the outlet gap is on the upper side of the left wall; Case B, the outlet is on left of the top wall; Case C, the outlet is at the middle of the top wall and Case D, the outlet is on right of the top wall of the cavity. From the results, it was concluded that, from a thermal comfort point of view and air quality, configuration D shows the best performance. In general, it is concluded that in order to obtain values that fulfill regulations of temperature and contaminant concentrations, it is required to have mixed convection with a Reynolds value of Re = 10,000.
机译:给出了在湍流状态下通风腔内空气-二氧化碳混合物(CO_2)的共轭传热和传质分析得到的数值结果。针对混合物出口间隙的位置分析了空腔的不同构造,以便研究空腔内的热行为和空气质量,并确定良好的通风构造。考虑了CO_2污染物源的四个不同值(500,1000、2000,3000 ppm)。进气间隙位于空腔的右垂直壁的下侧。进气速度是雷诺数的函数(5×10〜2≤Re≤4×10〜4)。混合物出口间隙的位置考虑在四个不同的位置:情况A,出口间隙在左壁的上侧;案例B,出口在顶壁的左侧;外壳C,出口在顶壁的中间,外壳D,出口在腔顶壁的右边。从结果可以得出结论,从热舒适性和空气质量的角度来看,配置D显示出最佳性能。总的来说,得出的结论是,为了获得满足温度和污染物浓度规定的值,需要具有雷诺数Re = 10,000的混合对流。

著录项

  • 来源
  • 作者单位

    Centro National de Investigacion y Desarrollo Tecnologico. CENIDET-DGEST-SEP, Prol. Av. Palmira S/N. Col. Palmira. Cuernavaca, Morelos CP. 62490, Mexico;

    Centro National de Investigacion y Desarrollo Tecnologico. CENIDET-DGEST-SEP, Prol. Av. Palmira S/N. Col. Palmira. Cuernavaca, Morelos CP. 62490, Mexico;

    Centro National de Investigacion y Desarrollo Tecnologico. CENIDET-DGEST-SEP, Prol. Av. Palmira S/N. Col. Palmira. Cuernavaca, Morelos CP. 62490, Mexico;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Ventilated room; Thermal comfort; Air quality;

    机译:通风室;热舒适性;空气质量;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号