首页> 外文期刊>International Journal of Heat and Mass Transfer >Experimental investigation on window ejected facade flame heights with different constraint side wall lengths and global correlation
【24h】

Experimental investigation on window ejected facade flame heights with different constraint side wall lengths and global correlation

机译:具有不同约束侧壁长度和整体相关性的窗户弹射门面火焰高度的实验研究

获取原文
获取原文并翻译 | 示例
       

摘要

This paper presents an experimental investigation on the effect of side wall length (normal to the facade direction) on the ejected facade flame height from a window of an under-ventilated compartment fire. The ejected facade flames are recorded by a CCD camera with various side wall lengths L at different side wall separation distances D. Results show that, as the length of the side wall increases, the change in behavior of the flame height can be categorized into two regimes: (1) the flame-entrainment-controlled regime in which flame height increases with side wall length for "(half) axisymmetric fire" but independent of side wall length for "wall fire"; and (2) the combustion-efficiency-controlled regime where the flame heights for both these two fire types decrease with side wall length due to decrease of the combustion efficiency inside the fire room, for L = 3D or greater. A global parameter K is then proposed based on scaling analysis for the air entrainment of the flame with side wall length, in relation to characteristic length scales ℓ_1 and ℓ_2 of the window, which well collapse the experimental data for different window dimensions, side wall lengths and separation distances.
机译:本文提出了一个实验研究,该实验研究了侧壁长度(垂直于立面方向)对从通风不足的隔室火窗射出的立面火焰高度的影响。 CCD摄像机以不同的侧壁间隔L在不同的侧壁间隔距离D下记录喷出的立面火焰。结果表明,随着侧壁长度的增加,火焰高度的变化可以分为两类。方案:(1)火焰夹带控制方案,其中“(半)轴对称火”的火焰高度随侧壁长度的增加而增加,而“壁火”的火焰高度随侧壁的长度而增加; (2)燃烧效率受控的方案,其中L = 3D或更大时,由于燃烧室内部燃烧效率的降低,这两种火灾类型的火焰高度均随着侧壁长度的增加而降低。然后基于比例分析针对与侧壁的特征长度标度ℓ_1和ℓ_2相关的侧壁长度的火焰夹带火焰,提出了一个全局参数K,这很好地折叠了不同窗户尺寸,侧壁长度的实验数据和分隔距离。

著录项

  • 来源
  • 作者单位

    State Key laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui 230026, China;

    State Key laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui 230026, China;

    State Key laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui 230026, China;

    State Key laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui 230026, China;

    State Key laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui 230026, China;

    State Key laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui 230026, China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Compartment fire; Side wall length; Facade; Flame height; Window; Global parameter;

    机译:车厢起火;侧壁长度;正面;火焰高度;窗口;全局参数;

相似文献