In this study, the capillary performance of the micro-post wicks with non-homogeneous configurations is investigated and compared with a conventional micro-post wick with homogeneous configuration. The experimental and numerical studies show that the capillary performance of the micro-post wick can be significantly enhanced, compared with the homogeneous type wick, by employing non-homogeneous configurations: a groove type wick and a square array type wick have 35% and 31% higher capillary performances, respectively, compared with the homogeneous type wick having equal post size. The capillary performance is shown to be primarily a function of the solid fraction and increases linearly with decreasing solid fraction, regardless of the wick configuration. However, the capillary performance is found to be significantly reduced when the solid fraction fails below a threshold value.
机译:在这项研究中,研究了具有非均质构造的微柱芯的毛细管性能,并将其与具有均一构造的常规微柱芯进行了比较。实验和数值研究表明,与非均质型芯相比,通过采用非均质配置,微柱芯的毛细性能可以得到显着提高:凹槽型芯和方阵型芯分别具有35%和31与具有相同柱尺寸的均质型芯相比,毛细管性能分别提高了5%。显示的毛细管性能主要是固体分数的函数,并且随芯分数的降低而线性增加,而与芯结构无关。然而,当固体分数低于阈值以下时,发现毛细管性能显着降低。

著录项

  • 来源
  • 作者

    Chan Byon; Sung Jin Kim;

  • 作者单位

    School of Mechanical Engineering, Yeungnam University, Gyeongsan 712-749, Republic of Korea;

    School of Mechanical, Aerospace & Systems Engineering, Korea Advanced Institute of Science and Technology, Daejeon 305-701, Republic of Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Micro-post wick; Capillary performance; Heat pipe;

    机译:微柱灯芯;毛细管性能;热管;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号