Present study deals with the flow boiling of R245fa, a commercial working fluid used in organic Rankine cycle, in brazed plate heat exchanger with chevron angle of 45 degree and 60 degree. The effects of the heat flux, mass flux rate of refrigerant, saturation temperature on convective heat transfer coefficients are investigated. The operating conditions of the experiment are as mass flux: 30-40 kg m~(-2) s~(-1) quality at evaporator inlet: 0.1-0.8, heat flux: 2-15 kW nrr~(-2). The heat transfer result suggests a nucleate boiling dominant process in the evaporator. The convective heat transfer coefficient showed a strong dependence on the heat flux and vapor quality at evaporator inlet. Moreover convective heat transfer coefficient show a linear relationship with mass flux of the refrigerant. It is worth mentioning that heat transfer coefficient is higher at higher saturation temperature and chevron angle. Based on the experimental data, empirical correlations were developed for the prediction of heat transfer coefficients and frictional pressure drop of refrigerant R245fa in brazed plate heat exchanger.
机译:目前的研究涉及在人字形角度为45度和60度的钎焊板式换热器中,有机朗肯循环中使用的商用工作流体R245fa的沸腾现象。研究了热通量,制冷剂质量通量率,饱和温度对对流换热系数的影响。实验的操作条件为:质量通量:蒸发器入口质量为30-40 kg m〜(-2)s〜(-1):0.1-0.8,热通量为2-15 kW nrr〜(-2)。传热结果表明蒸发器中的核沸腾占优势。对流换热系数显示出对蒸发器入口处的热通量和蒸汽质量的强烈依赖性。此外,对流换热系数与制冷剂的质量通量呈线性关系。值得一提的是,在较高的饱和温度和人字形角下,传热系数较高。基于实验数据,建立了经验相关性,用于预测钎焊板式换热器中制冷剂R245fa的传热系数和摩擦压降。

著录项

  • 来源
  • 作者单位

    Energy Engineering Department, School of Engineering, University of Management & Technology, C-II Johar Town Lahore, Pakistan,Energy Efficiency Research Division, Korea Institute of Energy Research, 152 Cajeong-ro, Yuseong-gu, Daejeon, Republic of Korea;

    Energy System Engineering, Korea University of Science and Technology, 217 Cajeong-ro, Yuseong-gu, Daejeon, Republic of Korea,Department of Mechanical Engineering University of Engineering & Technology, Lahore, C.T Rd, Lahore 54890, Pakistan;

    Energy System Engineering, Korea University of Science and Technology, 217 Cajeong-ro, Yuseong-gu, Daejeon, Republic of Korea,Energy Efficiency Research Division, Korea Institute of Energy Research, 152 Cajeong-ro, Yuseong-gu, Daejeon, Republic of Korea;

    Energy System Engineering, Korea University of Science and Technology, 217 Cajeong-ro, Yuseong-gu, Daejeon, Republic of Korea,Energy Efficiency Research Division, Korea Institute of Energy Research, 152 Cajeong-ro, Yuseong-gu, Daejeon, Republic of Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    flow boiling; organic rankine cycle; r245fa; two phase; plate heat exchanger; pressure drop; convective heat transfer;

    机译:流沸腾有机朗肯循环r245fa;两相板式换热器;压力下降;对流换热;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号