首页> 外文期刊>International Journal of Heat and Mass Transfer >Experimental investigation of high temperature thermal contact resistance of thin disk samples using infrared camera in vacuum condition
【24h】

Experimental investigation of high temperature thermal contact resistance of thin disk samples using infrared camera in vacuum condition

机译:真空条件红外摄像机薄盘样品高温热接触电阻的实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

High temperature thermal contact resistance between materials has significant influence on thermal design of many engineering applications. In this paper, an experimental setup was established to measure thermal contact resistance at high temperature based on steady state method. A data processing technique was developed to determine the thermal contact resistance. Moreover, the employment of thin disk samples was proved to be effective to ensure 1D axial heat flow by numerical prediction. The analyzed uncertainty of the test method is less than 10% with the validation of repeating experiments of HTA-HTA (high temperature Inconel 718 alloy). Additionally, thermal contact resistance of HTA-HTA, ZrB_2/SiC/C-ZrB_2/SiC/C (carbon fiber reinforced zirconium diboride and silicon carbide based composite) and HTA-ZrB_2/SiC/C were investigated varied with the temperature ranging from 630 to 1100 K and the pressure ranging from 0.1 to 0.6 MPa. The results show that thermal contact resistance decreases with increasing the interface temperature as the enhancement of radiative heat transfer. At the same time, thermal contact resistance decreases with increasing the interface pressure due to the increase of contact area, and the effects of pressure on thermal contact resistance is much lower at high temperature.
机译:材料之间的高温热接触电阻对许多工程应用的热设计具有显着影响。本文建立了一种实验设置,以稳态法测量高温热接触电阻。开发了一种数据处理技术以确定热接触电阻。此外,证明了薄盘样品的就业是有效的,以确保通过数值预测的1D轴向热流。随着HTA-HTA的重复实验(高温Inconel 718合金)的验证,测试方法的分析不确定性小于10%。另外,研究了HTA-HTA,ZRB_2 / SiC / C-ZRB_2 / SiC / C(碳纤维增强锆二硼化物和碳化硅基复合材料)和HTA-ZRB_2 / SiC / C的热接触电阻随温度范围为630到1100 k,压力范围为0.1至0.6MPa。结果表明,随着界面温度的增加,热接触电阻随着辐射传热的增强而降低。同时,随着接触面积的增加而增加,热接触电阻随着界面压力而增加,高温下压力对热接触电阻的影响远低得多。

著录项

  • 来源
    《International Journal of Heat and Mass Transfer》 |2020年第8期|119749.1-119749.11|共11页
  • 作者单位

    MIIT Key Laboratory of Thermal Control of Electronic Equipment School of Energy and Power Engineering Nanjing University of Science & Technology Nanjing 210094 China;

    MIIT Key Laboratory of Thermal Control of Electronic Equipment School of Energy and Power Engineering Nanjing University of Science & Technology Nanjing 210094 China;

    School of Mechanical and Electrical Engineering Guilin University of Electronic Technology Guilin 541004 China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Thermal contact resistance; High temperature; Experimental investigation;

    机译:热接触电阻;高温;实验调查;