首页> 外文期刊>International Journal of Heat and Mass Transfer >Pool boiling of horizontal mini-tubes in unconfined and confined columns
【24h】

Pool boiling of horizontal mini-tubes in unconfined and confined columns

机译:水平微型管在无限制和限制条件下的池沸腾

获取原文
获取原文并翻译 | 示例

摘要

Pool boiling on confined and unconfined tube columns was investigated. A model to predict bulk void fraction in a confined tube column was developed and validated experimentally, returning a mean predictive accuracy of 12.5%. A semi-empirical model was also developed from bubble plume images to evaluate bulk void fraction in an unconfined plume around a tube column. Within an unconfined plume, void fraction increases monotonically with column height, indicating that a column height exists beyond which the mean column heat transfer coefficient is adversely affected by dryness. Pool boiling experiments were undertaken in Novec 649 to investigate the effects of external confinement, tube spacing, and column height on heat transfer. Increasing the column height in a column showed an initial decline in power density to a constant at similar to 30 MW m(-3). A tube void fraction threshold was identified as changing the location of critical heat flux from the bottom tube to the top tube in a column, and to cause a deterioration in tube heat transfer coefficient at high heat fluxes. (C) 2019 Elsevier Ltd. All rights reserved.
机译:研究了密闭管柱上的池沸腾情况。开发了一种模型来预测密闭管柱中的空洞率,并进行了实验验证,得出的平均预测准确度为12.5%。还从气泡羽流图像开发了一个半经验模型,以评估围绕管柱的无限制羽流中的体积空隙率。在无限制的羽状流中,空隙率随柱高单调增加,表明存在柱高,超过该柱高,柱平均传热系数会受到干燥的不利影响。在Novec 649中进行了池沸腾实验,以研究外部约束,管间距和塔高对传热的影响。增加塔中的塔高显示出功率密度的初始下降到一个恒定的常数,类似于30 MW m(-3)。管空隙分数阈值被确定为改变了从塔中的底部管到顶部管的临界热通量的位置,并导致在高热通量下管传热系数的降低。 (C)2019 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号