摘要

An experimental investigation is performed to evaluate the performance of an integrated hotbox in a 1-kW solid oxide fuel cell (SOFC) system fed by natural gas. The integrated hotbox comprises all the main balance of plant components of an SOFC system, i.e. afterburner, reformer, and heat exchanger, and it not only reduces the physical size of the system but also yields improved system efficiency. The experimental results show that under optimal operating conditions, the combined H-2 and CO content of the reformate gas is approximately 70%, while both anode and cathode in-gas temperatures are around approximately 750 degrees C.
机译:进行了一项实验研究,以评估由天然气供气的1kW固体氧化物燃料电池(SOFC)系统中集成热箱的性能。集成式热箱包括SOFC系统工厂组件的所有主要平衡,即加力燃烧器,重整器和热交换器,它不仅减小了系统的物理尺寸,而且提高了系统效率。实验结果表明,在最佳操作条件下,重整气的H-2和CO含量之和约为70%,而阳极和阴极的进气温度均约为750摄氏度。