Optimal strategy for algae control in potable water treatment facilities

机译:饮用水处理设施中藻类控制的最佳策略

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This paper presents both a current review of the state-of-the-art in algae removal, and an experimental study of algae removal in potable water supply. Established techniques were investigated by jar-testing on surface raw water samples derived from a lowland river, with the dominant species of algae being Scenedesmus sp (a green algae). These tests were conducted both in isolation and in combination to determine the optimum operational strategy for an actual water treatment facility. Employing 1 mg/L of CuSO_4 could remove algae by up to 50.6%, though this might lead to the release of algal toxin. The most effective single technique was PAC addition, which could reduce the algae population by up to 97.6%, although doses above 30 mg/L created turbidity. The maximum reduction ratio achieved with polyaluminium chloride in the absence of pH control was 79.1%, employing a dosage of 14 mg/L; careful pH control during addition of poly-AlCl_3 coagulant increased algae removal by up to 35%.
机译:本文既介绍了当前除藻技术的最新进展,也介绍了饮用水中除藻的实验研究。通过对来自低地河流的地表原水样品进行广口瓶测试,研究了已建立的技术,其中藻类的主要物种为Scenedesmus sp(绿藻)。这些测试是单独进行或组合进行的,以确定实际水处理设施的最佳运行策略。使用1 mg / L的CuSO_4最多可以去除50.6%的藻类,尽管这可能导致藻类毒素的释放。最有效的单一技术是添加PAC,尽管剂量超过30 mg / L会产生浑浊,但它最多可以减少97.6%的藻类种群。在没有pH控制的情况下,采用14mg / L的剂量时,聚氯化铝的最大还原率为79.1%。在添加聚-AlCl_3混凝剂期间仔细控制pH值,可将藻类去除率提高多达35%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号