A chemical and mass-spectrometric procedure for uranium isotopic analysis using a thermal ionisation mass spectrometer equipped with a Wide Aperture Retardation Potential energy filter has been developed and applied to uranium isotopic measurements for various soil samples. Soil samples were digested using a microwave digestor. Uranium was isolated from soii samples by the chemical separation procedure based on the use of anion-exchange resin and UTEVA extraction chromatography column. The isotope ratios were measured for two certified reference materials by using a VG Sector 54-30 thermal ionisation mass spectrometer in dynamic mode with Faraday cup and Daly ion counting system. Replicates of standard reference materials showed excellent analytical agreement with established values supporting the reliability and accuracy of the method. Precision of the ~(235)U/~(238)U ratio was achieved by a correction factor of 0.22% amu as a function of ion-beam intensity with sample loads of around 250 ng of U. The resulting reproducibility for standards and soil samples was better than 0.2% at two standard deviations (SD). Uranium isotopic compositions have been determined in several reference soil samples such as Buffalo river sediment, NIST 2704, river sediment SRM 4350b and ocean sediment NIST-4357 and a Chernobyl soil sample. There was a significant deviation from the natural uranium in comparison with Chernobyl soil samples.
机译:已开发出一种化学和质谱分析程序,该程序使用配备了宽孔径延迟势能过滤器的热电离质谱仪进行铀同位素分析,并将其应用于各种土壤样品的铀同位素测量。土壤样品用微波消解器消解。通过使用阴离子交换树脂和UTEVA萃取色谱柱的化学分离程序从大豆样品中分离铀。通过使用带有Faraday杯和Daly离子计数系统的动态模式下的VG Sector 54-30热电离质谱仪,测量了两种认证参考物质的同位素比。标准参考物质的重复试验显示出极好的分析一致性,其既定值支持方法的可靠性和准确性。 〜(235)U /〜(238)U比率的精确度是通过0.22%amu的校正因子来实现的,该校正因子是离子束强度的函数,样品负载约为250 ngU。所得标准品和土壤的重现性在两个标准差(SD)下,样品均优于0.2%。已在几种参考土壤样品中确定了铀同位素组成,例如布法罗河沉积物,NIST 2704,河流沉积物SRM 4350b和海洋沉积物NIST-4357和切尔诺贝利土壤样品。与切尔诺贝利土壤样品相比,天然铀有明显的偏差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号