Column-mode Separation And Pre-concentration Of Some Heavy Metalions By Solvent-impregnated Resins Containing Quinizarin Before The determination By Flame Atomic Absorption Spectrometry

机译:火焰原子吸收光谱法测定含奎尼沙林的溶剂浸渍树脂的柱模式分离和预富集一些重金属离子

获取原文
获取原文并翻译 | 示例
           

摘要

A simultaneous separation and pre-concentration of Cd(II), Cu(II), Ni(II) and Zn(II) ions from natural water samples for subsequent flame atomic absorption spectrometric determination was proposed. The procedure is based on sorption of the metal ions at the buffering pH of 9.5, on a short column filled with Amberlite XAD-16 impregnated with the complexing agent of 1,4-dihydroxyanthraquinone (quinizarin). The determinations, without the interference of the co-existing substances, were carried out after metals elution with 5mL of 0.5mol L~(-1) HCl. A pre-concentration factor of nearly 100 was obtained using aliquots of 500 mL of the sample solution. For the optimisation of the procedure, effects of sample and eluent flow rate, eluent concentration and its volume were investigated. Beer's law was obeyed in the range of 5.0 × 10~(-9) to 1.0 × 10~(-7)mol L~(-1) for Cd(II) and Zn(Il), 5.0 × 10~(-8) to 1.0 × 10~(-6) mol L~(-1) for Cu(II) and Ni(II) ions. The relative standard deviations of the determinations were <1.87%. The limit of detections for Cd(II), Cu(II), Ni(II) and Zn(II) were found to be 1.3 × 10~(-9), 7.1 × 10~(-9), 1.3 × 10~(-8) and 1.8 × 10 mol L~(-1), respectively. The practical applicability of the method was confirmed using a synthetic certificated reference material and spiked natural water samples.
机译:提出了同时分离和预富集天然水中样品中Cd(II),Cu(II),Ni(II)和Zn(II)离子的方法,用于随后的火焰原子吸收光谱测定。该程序是基于在填充了Amberlite XAD-16的短柱上,在9.5的缓冲pH值下金属离子的吸附,Amberlite XAD-16浸渍了1,4-二羟基蒽醌(喹唑啉)的络合剂。在用5mL的0.5mol L〜(-1)HCl进行金属洗脱后,进行测定,不受共存物质的干扰。使用500 mL样品溶液的等分试样可获得接近100的预浓缩系数。为了优化程序,研究了样品和洗脱液流速,洗脱液浓度及其体积的影响。 Cd(II)和Zn(Il)的啤酒定律在5.0×10〜(-9)至1.0×10〜(-7)mol L〜(-1)范围内,5.0×10〜(-8) Cu(II)和Ni(II)离子的摩尔比为1.0×10〜(-6)mol L〜(-1)。测定的相对标准偏差<1.87%。发现Cd(II),Cu(II),Ni(II)和Zn(II)的检出限为1.3×10〜(-9),7.1×10〜(-9),1.3×10〜 (-8)和1.8×10 mol L〜(-1)。该方法的实际适用性通过使用合成认证参考材料和加标天然水样品得到了证实。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号