首页> 外文期刊>International journal of environmental analytical chemistry >A spectrophotometric method for manganese determination in water samples based on ion pair formation and dispersive liquid-liquid microextraction
【24h】

A spectrophotometric method for manganese determination in water samples based on ion pair formation and dispersive liquid-liquid microextraction

机译:基于离子对形成和分散液-液微萃取的分光光度法测定水样中的锰

获取原文
获取原文并翻译 | 示例

摘要

In this work, a simple, inexpensive, and environmentally friendly extractive spectrophotometric method for the determination of manganese is suggested. The method is based on the formation and dispersive liquid-liquid microextraction (DLLME) of a violet-coloured ion pair of Mn(II) with l,3,3-trimethyl-2-[3-(3-methyl-3H-benzothiazol-2-ylidene)-propenyl]-3H-indolium (BTIC) in the presence of l-nitroso-2-naphthol (HL) as ligand, and subsequent UV-VIS spectrophotometric detection at 560 nm of the ion pair formed. The appropriate experimental conditions for the DLLME procedure were found to be: a pH of 9.5; 0.12 mmol L~(-1) of BTIC; extraction solvent - toluene containing 1.75 mmol L~(-1) of HL; disperser solvent - methanol; auxiliary solvent - tetrachloromethane. Beer's law is obeyed in the range 0.055-0.88 μg mL~(-1) of Mn(II). The limit of detection (LOD), calculated based on three times of the standard deviation of the blank test (n=10), was found to be 0.004 ugm L~(-1) of Mn(II). The precision (as relative standard deviation, RSD%) and accuracy (as recovery percentage, R%) of the method were examined by performing five replicate determinations at four concentration levels over two days and varied between 1.2 and 3.8, and 97.7 and 104.5, respectively. The suggested method was successfully applied to the analysis of various water samples (mineral water, spring water and drinking water).
机译:在这项工作中,提出了一种测定锰的简单,廉价且环保的萃取分光光度法。该方法基于Mn(II)与1,3,3-三甲基-2- [3-(3-甲基-3H-苯并噻唑)的紫色离子对的形成和分散液-液微萃取(DLLME)在1-亚硝基-2-萘酚(HL)作为配体存在下,将-2-亚丙基)-丙烯基] -3H-吲哚(BTIC),随后在560 nm的离子对上进行UV-VIS分光光度法检测。发现DLLME程序的合适实验条件是:pH为9.5; pH为9.5。 0.12 mmol L〜(-1)的BTIC;萃取溶剂-含有1.75 mmol L〜(-1)HL的甲苯;分散剂-甲醇;辅助溶剂-四氯甲烷。在Mn(II)的0.055-0.88μgmL〜(-1)范围内遵守比尔定律。根据空白试验的标准偏差的三倍(n = 10)计算得出的检出限(LOD)为Mn(II)的0.004 ugm L〜(-1)。该方法的精密度(相对标准偏差,RSD%)和准确度(回收率,R%)通过在两天内在四个浓度水平下进行五次重复测定来检验,测定范围为1.2和3.8,以及97.7和104.5,分别。所建议的方法已成功应用于各种水样(矿泉水,泉水和饮用水)的分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号