We developed glucose biosensors coated with biocompatible polymers to rapidly monitor glucose levels in free-swimming fish. Biocompatible polymers have a similar structure to living organisms and are thus used to make metallic materials more compatible with the living body. We focused on three widely used biocompatible polymers, 2-methacryloyloxyethyl phosphorlycholine (MPC) polymers, polypyrroles, and polyurethanes, to achieve biocompatibility of our glucose biosensor. The developed glucose biosensor has a Pt-Ir wire (φ0.178mm) as the working electrode and Ag/AgCl paste as the reference electrode. The bipsensor was first coated with Nafion to prevent coexisting substances such as ascorbic acid and uric acid from interfering with the sensor output current, and then glucose oxidase (GOx) was fixed on top of the Nafion layer along with biocompatible polymers. The sensor was inserted into the fish eyeball interstitial scleral fluid (EISF), which contains low levels of proteins and correlates well with the glucose levels in the whole blood. Those three sensors were tested for durability and sensors coated with MPC polymers (Nafion/GOx/MPC sensor) proved to be most durable: the sensor output current maintained 93% output for 15 h in standard glucose solution, and 80% in EISF for 8 h, whereas the output current of the other sensors decreased more rapidly overtime. We then inserted Nafion/GOx/MPC sensor to wirelessly monitor EISF glucose levels in free-swimming fish. One-point calibration method was used to calibrate the sensor output current. As a result, 24 h of wireless monitoring was successfully achieved.
机译:我们开发了涂有生物相容性聚合物的葡萄糖生物传感器,以快速监测自由游动鱼类的葡萄糖水平。生物相容性聚合物的结构与生物体相似,因此可用于使金属材料与生物体更加相容。我们专注于三种广泛使用的生物相容性聚合物,即2-甲基丙烯酰氧基乙基磷胆碱(MPC)聚合物,聚吡咯和聚氨酯,以实现我们的葡萄糖生物传感器的生物相容性。研发的葡萄糖生物传感器以一根Pt-Ir线(φ0.178mm)作为工作电极,并以Ag / AgCl糊剂作为参比电极。首先为Bipsensor涂上Nafion,以防止抗坏血酸和尿酸等共存物质干扰传感器输出电流,然后将葡萄糖氧化酶(GOx)与生物相容性聚合物固定在Nafion层的顶部。该传感器被插入鱼眼间质巩膜液(EISF)中,该液中蛋白质含量低,并且与全血中的葡萄糖含量良好相关。对这三个传感器进行了耐久性测试,并证明涂覆有MPC聚合物的传感器(Nafion / GOx / MPC传感器)最耐用:在标准葡萄糖溶液中,传感器输出电流在15小时内保持93%的输出,在EISF中保持80%的输出8 h,而其他传感器的输出电流随着时间的推移会更快地下降。然后,我们插入了Nafion / GOx / MPC传感器,以无线方式监测自由游动鱼类的EISF葡萄糖水平。一站式校准方法用于校准传感器输出电流。结果,成功实现了24小时的无线监控。

著录项

  • 来源
  • 作者单位

    Faculty of Marine Science, Tokyo University of Marine Science and Technology, Konan, Minato-ku, Tokyo 108-8477, Japan;

    Faculty of Marine Science, Tokyo University of Marine Science and Technology, Konan, Minato-ku, Tokyo 108-8477, Japan;

    Hokkaido Industrial Technology Center, Hakodate, Hokkaido 041-0801, Japan;

    Faculty of Marine Technology, Tokyo University of Marine Science and Technology, Etchujima, Koto-ku, Tokyo 135-8533, Japan;

    Faculty of Marine Science, Tokyo University of Marine Science and Technology, Konan, Minato-ku, Tokyo 108-8477, Japan;

    Faculty of Marine Science, Tokyo University of Marine Science and Technology, Konan, Minato-ku, Tokyo 108-8477, Japan;

    Faculty of Marine Science, Tokyo University of Marine Science and Technology, Konan, Minato-ku, Tokyo 108-8477, Japan;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    biosensor; fish; glucose; blood; wireless; monitoring;

    机译:生物传感器鱼;葡萄糖;血液;无线;监控;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号