To effectively diminish harmonic distortions, the locations of harmonic sources have to be identified and their currents have to be separated from that absorbed by conventional linear loads connected to the same CCP. In this paper, based on the intrinsic difference between linear and nonlinear loads in their Ⅴ-Ⅰ characteristics and by utilizing a new simplified harmonic source model, a new principle for harmonic source identification and harmonic current separation is proposed. By using this method, not only the existence of harmonic source can be determined, but also the contributions of the harmonic source and the linear loads to harmonic voltage distortion can be distinguished. The detailed procedure based on least squares approximation is given. The effectiveness of the approach is illustrated by test results on a composite load.
机译:为了有效减少谐波失真,必须确定谐波源的位置,并且必须将其电流与连接到同一CCP的常规线性负载吸收的电流分开。本文基于线性和非线性负载的Ⅴ-Ⅰ特性之间的固有差异,并利用新的简化谐波源模型,提出了一种新的谐波源识别和谐波电流分离原理。通过这种方法,不仅可以确定谐波源的存在,而且可以区分出谐波源和线性负载对谐波电压畸变的贡献。给出了基于最小二乘近似的详细过程。通过在复合负载上的测试结果来说明该方法的有效性。