Sufficient fast secondary reserve and its adequate dynamic activation are the key factors in satisfying automatic generation control (AGC) performance of a power system. Dynamic activation of the secondary reserves should also not introduce any negative damping to inter-area oscillations. This study presents a strategy to enhance AGC performance of a power system considering these concerns. Objective function is minimizing the amount of fast secondary reserves to mitigate ancillary service cost. The constraints are; AGC performance indices should be acceptable and AGC parameter settings should be adequate for inter-area oscillation concerns. In order to facilitate dynamic simulations, it is proposed to utilize a representative single bus common frequency dynamic model (SBCFDM) of the power system. The proposed strategy is based on optimizing the AGC parameters only for the time horizon when the loads are fluctuating most. Adequacy of the optimized AGC parameters are checked only for the worst loading scenario from inter-area oscillations concern point of view. It is showed that dynamic allocation of the secondary reserves twice a day is sufficient for satisfactory results. The proposed strategy is verified by its application to Turkish power system which suffers significant amount of fluctuating loads and inter-area oscillations with ENTSO/E grid.
机译:足够的快速二次储备及其足够的动态激活是满足电力系统自动发电控制(AGC)性能的关键因素。动态激活次要储备也不应对区域间振荡产生任何负阻尼。考虑到这些问题,本研究提出了一种提高电力系统AGC性能的策略。目标功能是最大程度地减少快速二级储备的数量,以减轻辅助服务成本。约束是; AGC性能指标应可接受,并且AGC参数设置应足以应对区域间振荡问题。为了促进动态仿真,提出了利用电力系统的代表性单总线公共频率动态模型(SBCFDM)。所提出的策略基于仅在负载波动最大的时间范围内优化AGC参数。从区域间振荡问题的角度来看,仅针对最坏的负载情况检查优化的AGC参数是否足够。结果表明,每天两次动态分配次要储备足以获得令人满意的结果。该策略通过在土耳其电力系统中的应用得到了验证,该电力系统承受着很大的波动负载,并且在ENTSO / E电网中会发生区域间振荡。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号