摘要

In this paper an analytical design method is proposed for constant voltage controlled inverter based DG with frequency dependent ZIP-Exponential static load model to obtain proper inverter output control and successful islanding detection. The proposed technique is aimed to eliminate the dependency of DG operation point on anti-islanding performance which is unavoidable in case of traditional control strategy. The generalized formulae are derived for calculating the upper and lower limits of the voltage gain, and it is recommended to select the voltage gain within the designed range for effective islanding detection. The proposed approach is tested in MATLAB/Simulink environment and result shows that the proposed scheme is found to be highly effective in islanding detection considering complex network configurations with single and multiple DG systems. The proposed control scheme is able to detect islanding within 10 ms (half cycle) from the event inception, showing the fastness of the developed technique. It is also observed that the percentage of voltage and current THD of the proposed scheme is within permissible limits, indicate that the power quality'of the inverter is not degraded by the proposed control strategy, and thus overcomes the drawback of existing active anti-islanding techniques. (C) 2015 Elsevier Ltd. All rights reserved.
机译:本文提出了一种基于频率的ZIP指数静态负载模型的恒压控制逆变器DG的解析设计方法,以获得适当的逆变器输出控制和成功的孤岛检测。所提出的技术旨在消除DG操作点对防孤岛性能的依赖性,这在传统控制策略的情况下是不可避免的。推导了通用公式来计算电压增益的上限和下限,建议在设计范围内选择电压增益以进行有效的孤岛检测。在MATLAB / Simulink环境中测试了该方法,结果表明,考虑到具有单个和多个DG系统的复杂网络配置,该方法在孤岛检测中非常有效。所提出的控制方案能够在事件发生后的10 ms(半个周期)内检测到孤岛,显示出所开发技术的快速性。还可以观察到,所提出的方案的电压和电流THD的百分比在允许的范围内,表明所提出的控制策略不会降低逆变器的电能质量,从而克服了现有主动抗孤岛的缺点。技术。 (C)2015 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号