This paper proposes a method to compensate the network voltage unbalance using the doubly fed induction generator (DFIG) wind turbine connected to a dynamic voltage restorer (DVR). In the configuration employed, a DVR based on a voltage-source converter is connected in series between the generator and the grid. The proposed control uses symmetrical components to calculate the negative sequence current to be injected in the network to compensate the voltage unbalance at the Point of Common Coupling (PCC), and the voltage to be applied at the stator, to avoid torque oscillations. The contribution of this paper consists on proposing a coordinated strategy for compensating the voltage unbalance at PCC and avoiding torque oscillations in the machine. Due to the coordinated use of all resources available for compensation, the proposed method increases the operational range of the existing methods. Basically, the strategy of the proposed method consists on using the remain capacity of the grid side converter of the DFIG for injecting compensating current and, when it reaches its limit, the rotor side converter is controlled to inject compensating current through the machine stator to the grid. The torque oscillations due to the unbalanced operation of the machine is avoided by applying a series voltage by the DVR. Simulation results have validated the proposed method, which maximizes the compensation at the PCC voltage unbalance and guarantees the machine operation with low oscillation in the electromagnetic torque.
机译:本文提出了一种使用双馈感应发电机(DFIG)风力涡轮机连接到动态电压恢复器(DVR)来补偿网络电压不平衡的方法。在采用的配置中,基于电压源转换器的DVR串联连接在发电机和电网之间。所提出的控制使用对称分量来计算要注入网络的负序电流,以补偿公共耦合点(PCC)处的电压不平衡以及施加在定子上的电压,从而避免转矩振荡。本文的贡献在于提出一种协调策略,以补偿PCC处的电压不平衡并避免电机中的扭矩振荡。由于协调使用了所有可用于补偿的资源,因此所提出的方法扩大了现有方法的可操作范围。基本上,所提出方法的策略包括使用DFIG的电网侧变流器的剩余容量注入补偿电流,当达到极限时,控制转子​​侧变流器通过电机定子向电动机注入补偿电流。网格。通过DVR施加串联电压,可以避免由于机器不平衡运行而引起的转矩振荡。仿真结果验证了该方法的有效性,该方法可以最大程度地补偿PCC电压不平衡时的补偿,并保证电机运行时电磁转矩的波动小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号