摘要

Accurate, simple identification and suppression of repetitive commutation failures are of great significance to the safe and stable operation of the line-commutated converter-based high-voltage direct current (LCC-HVDC). Through the analysis of mathematical models of inverter side converter and DC transmission system. This paper proposes a variable that has an important influence on commutation failure: equivalent DC input resistance. Therefore, a measurement method is proposed, which takes into account the phase deviation of the fundamental commutation line voltage and uses equivalent DC input resistance as the input of the established mathematical model to measure the extinction angle. Meanwhile, according to the characteristics of equivalent DC input resistance, a method based on constant equivalent DC input resistance (EDCIR) to suppress repetitive commutation failures is proposed. Finally, several simulations are conducted on the CIGRE HVDC benchmark and GuiguangII model to validate the effectiveness of the proposed measurement method(TPMM) in the accuracy and suppression of commutation failure. The simulation results show that the proposed measurement method has the same accuracy as the measured extinction angle method and is higher than that of the minimum voltage drop method commonly used in practical engineering in judging commutation failure. At the same time, the proposed method to suppress can effectively reduce the number of commutation failures under single-phase and threephase ground faults comparing with voltage-dependent current order limiter (VDCOL) and commutation failure prevention and control (CFPREV).
机译:重复换向故障的准确性,简单的识别和抑制对基于线路换向转换器的高压直流(LCC-HVDC)的安全和稳定运行具有重要意义。通过逆变器侧转换器和直流传输系统的数学模型分析。本文提出了一种对换向故障产生重要影响的变量:等效直流输入电阻。因此,提出了一种测量方法,其考虑了基本换向线电压的相位偏差,并使用等效的DC输入电阻作为确定的数学模型的输入来测量消光角。同时,根据等效DC输入电阻的特性,提出了一种基于恒定等效DC输入电阻(EDCIR)来抑制重复换向故障的方法。最后,在CIGRE HVDC基准和Guiguangii模型上进行了几种模拟,以验证所提出的测量方法(TPMM)在换向故障的准确性和抑制中的有效性。仿真结果表明,所提出的测量方法具有与测量的消光角法相同的精度,并且高于在判断换向故障中实际工程中常用的最小电压降法的精度。同时,提出的抑制方法可以有效地减少单相和三相接地故障下的换向故障的数量与电压相关的电流订单限制器(VDCOR)和换向故障防护(CFPREV)相比。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号