One of the key features of a three/single-phase multimicrogrid (MMG) is the ability to transition between the grid-connected mode and the islanded mode. A seamless unintentional transition to the islanded mode is necessary for a three/single-phase MMG to achieve power balance and reliable operation. However, when the utility grid fails and the three/single-phase MMG unintentionally switches from the grid-connected mode to the islanded mode, the transition process can cause three-phase imbalance and power shortage problems. To solve these problems, this paper proposes a seamless unintentional transition control strategy for a three/single-phase MMG composed of a quick learning-to-rank combination method and a load shedding control strategy. In the proposed seamless transition control strategy, a quick learning-to-rank combination method that transforms a single-phase source-load-storage into a virtual three-phase load (VTL) is proposed to solve the three-phase imbalance problem. In addition, a load shedding control strategy based on a coordinated load shedding factor (CLSF) is proposed to solve the power shortage problem. The performance of the proposed strategy is verified for a three/single-phase MMG model based on a modified IEEE 37-bus system. During the unintentional islanding period, the proposed strategy reduces the three-phase imbalance by 0.36% and 0.13%, the range of frequency fluctuations by 26.42% and 17.02%, and the frequency recovery time by 36.59% and 29.73% compared with the implicit enumeration strategy (IES) and the compound implicit enumeration strategy (CIES), respectively. The test results show that the proposed strategy can reduce the three-phase imbalance, reduce the range of frequency fluctuations, and ensure the power supply reliability for critical loads during the unintentional islanding period.
机译:三个/单相多米列格(MMG)的关键特征之一是能够在网格连接模式和岛状模式之间转换。对于三个/单相MMG来实现功率平衡和可靠操作是必要的无缝无意过渡。但是,当实用网格失败并且三个/单相MMG无意地从电网连接模式切换到岛屿模式,过渡过程会导致三相不平衡和功率短缺问题。为了解决这些问题,本文提出了一个由快速学习 - 排序组合方法和负载脱落控制策略组成的三个/单相MMG的无缝无意过渡控制策略。在所提出的无缝转换控制策略中,提出了一种快速学习 - 排名组合方法,将单相源加载存储器转换为虚拟三相负载(VTL),以解决三相不平衡问题。另外,提出了一种基于协调负载脱落因子(CLSF)的负载脱落控制策略来解决功率短缺问题。基于修改的IEEE 37总线系统,为三/单相MMG模型验证了所提出的策略的性能。在无意的岛屿期间,拟议的策略将三相失衡降低0.36%和0.13%,频率波动范围为26.42%和17.02%,与隐性枚举相比,频率恢复时间为36.59%和29.73%策略(IES)和复合隐性枚举策略(CIE)。测试结果表明,该策略可以减少三相失衡,降低频率波动范围,并确保在无意岛期期间临界负荷的供电可靠性。

著录项

  • 来源
    《International journal of electrical power and energy systems》 |2021年第12期|107257.1-107257.12|共12页
  • 作者单位

    China Three Gorges Univ Yichang Key Lab Intelligent Operat & Secur Def Po Yichang 443002 Peoples R China|China Three Gorges Univ Coll Elect Engn & New Energy Yichang 443002 Peoples R China;

    China Three Gorges Univ Yichang Key Lab Intelligent Operat & Secur Def Po Yichang 443002 Peoples R China|China Three Gorges Univ Coll Elect Engn & New Energy Yichang 443002 Peoples R China;

    State Grid Anhui Elect Power Co Ltd Guangde Power Supply Co Xuancheng 242000 Peoples R China;

    Hubei Energy Grp Ezhou Power Co Ltd Ezhou 436000 Peoples R China;

    State Grid Hubei DC Operat & Maintenance Co Yichang 443000 Peoples R China;

    State Grid Hubei DC Operat & Maintenance Co Yichang 443000 Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Multimicrogrid; Seamless transition; Power shortage; Critical load;

    机译:多米根格;无缝过渡;功率短缺;关键负载;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号