HVDC transmission systems using voltage source converters (VSC-HVDC) have been identified as an attractive solution for bulk power delivery over long distance. However if DC grids are to be built using this technology, fast DC circuit breakers are needed. This work proposes a new hybrid DC circuit breaker utilizing a series connected coupled inductor connected, which enables automatic current commutation from the mechanical switch to the semiconductor switch during a fault. The key advantage of the proposed DC circuit breaker is that the current in the mechanical switch automatically reduces to zero when a fault happens. This paper focuses on comparison of different mechanisms to commutate the current from the mechanical switch to the semiconductor switch and create a zero current for the mechanical switch. Three types of hybrid DC circuit breaker topologies including proactive hybrid DC circuit breaker, hybrid DC circuit breaker with commutation booster, and hybrid DC circuit breaker with coupled inductor for a 500 kV HVDC system are simulated and compared using Matlab/Simulink. A prototype hybrid DC circuit breaker with coupled inductor is designed and built. The prototype is capable of interrupting 200 A direct current within 4 ms. The automatic current commutation compensates for the fault detection and location time in the selective protection scheme, which provides faster fault current interruption.
机译:使用电压源转换器(VSC-HVDC)的HVDC传输系统已被识别为具有长距离的散装电源的有吸引力的解决方案。但是,如果使用该技术建立直流网格,则需要快速的直流断路器。该工作提出了一种新的混合直流断路器,利用连接的串联连接耦合电感器,其在故障期间使从机械开关到半导体开关的自动换向。所提出的直流断路器的关键优势在于,当发生故障时,机械开关中的电流会自动降低到零。本文侧重于不同机制对从机械开关向半导体开关的电流进行比较,并为机械开关产生零电流。三种类型的混合直流断路器拓扑,包括主动混合直流断路器,具有换向增压器的混合直流断路器,以及具有500kV HVDC系统的耦合电感器的混合直流断路器,并使用MATLAB / Simulink进行比较。设计和构建具有耦合电感器的原型混合直流断路器。原型能够在4毫秒内中断200直流电。自动电流换向可补偿选择保护方案中的故障检测和位置时间,可提供更快的故障电流中断。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号