首页> 外文期刊>International Journal of Earthquake and Impact Engineering >Optimal damper placement in hybrid control system of multiple isolation and building connection
【24h】

Optimal damper placement in hybrid control system of multiple isolation and building connection

机译:多重隔离和建筑物连接的混合控制系统中的最佳风门位置

获取原文
获取原文并翻译 | 示例
       

摘要

An algorithm for optimal damper placement is proposed in a hybrid control system of multiple isolation and building connection. Such innovative hybrid control building system has been proposed recently, It is a great concern whether the seismic displacement response at the base-isolation layer of the existing base-isolated buildings may be amplified under long-period and long-duration ground motions. In order to enhance the robustness on the seismic performance of those base-isolated buildings, a novel hybrid system of multiple isolation and building-connection has been proposed and compared with other structural systems such as an independent multiple isolation system, a hybrid system of base-isolation and building-connection in the previous paper. It has been made clear that such hybrid control system possesses a remarkable performance for various types of earthquake ground motions. After the investigation of the effective location of the middle isolation story, a sensitivity-based optimisation algorithm is proposed for optimal connection damper placement in such hybrid control system.
机译:在多重隔离和建筑物连接的混合控制系统中,提出了一种最佳风门位置的算法。近年来,已经提出了这种创新的混合控制建筑物系统。在长期和长期的地面运动下,现有的基础隔离建筑物的基础隔离层的地震位移响应是否会被放大是一个令人非常关注的问题。为了提高这些基础隔震建筑物的抗震性能的鲁棒性,提出了一种新型的多重隔震和建筑物连接的混合系统,并将其与其他结构系统进行比较,例如独立的多重隔震系统,基础的混合系统。隔离和建筑物连接已经清楚地表明,这种混合控制系统对于各种类型的地震地面运动具有卓越的性能。在研究了中间隔离层的有效位置之后,提出了一种基于灵敏度的优化算法,用于在这种混合控制系统中优化连接阻尼器的位置。

著录项

  • 来源
  • 作者单位

    Department of Architecture and Architectural Engineering, Graduate School of Engineering, Kyoto University, Kyotodaigaku-Katsura, Nishikyo, Kyoto 615-8540, Japan;

    Department of Architecture and Architectural Engineering, Graduate School of Engineering, Kyoto University, Kyotodaigaku-Katsura, Nishikyo, Kyoto 615-8540, Japan;

    Department of Architecture and Architectural Engineering, Graduate School of Engineering, Kyoto University, Kyotodaigaku-Katsura, Nishikyo, Kyoto 615-8540, Japan;

    Department of Architecture and Architectural Engineering, Graduate School of Engineering, Kyoto University, Kyotodaigaku-Katsura, Nishikyo, Kyoto 615-8540, Japan;

    Department of Architecture and Architectural Engineering, Graduate School of Engineering, Kyoto University, Kyotodaigaku-Katsura, Nishikyo, Kyoto 615-8540, Japan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    multiple isolation; building-connection control; hybrid passive control system; robustness; redundancy; optimal damper location.;

    机译:多重隔离建筑物连接控制;混合被动控制系统;健壮性冗余;最佳风门位置。;