首页> 外文期刊>International Journal of Civil Engineering,Transaction A:Civil Engineering >Undrained Shear Strength and Pore Pressure Changes Due to Prestress Concrete Pile Installation in Soft Clay
【24h】

Undrained Shear Strength and Pore Pressure Changes Due to Prestress Concrete Pile Installation in Soft Clay

机译:预应力混凝土桩在软土地基中安装后的不排水抗剪强度和孔隙压力变化

获取原文
获取原文并翻译 | 示例
           

摘要

This study focuses on the changes of undrained shear strength (S-u) and pore pressure (u(2)) due to the installation of prestress concrete pile (PCP) in Fujian marine soft clay in China. The changes of S-u values due to PCP installation are measured by vane shear test (VST) investigation. The piezocone penetration testing (CPTU) is conducted for detecting the change of pore pressure when the PCPs are driven one by one according to the predesigned PCPs construction sequence. The results show that the Su-post values of Fuzhou soft clay are lost about 17% and the Su-post300 value is 1.36 times as much as Su-pre value. It is also shown that three fitting straight lines of Su-pre, Su-post, and Su-post300 are almost parallel which helps predicting the S-u value with different depths. The relationship between the normalized excess pore pressure, u/sigma(v0), and the ratio of radial distance to pile radius, lg(r/R), is also proposed based on CPTU data, which can be used to predict the excess pore pressure from different distance.
机译:这项研究的重点是由于在中国福建海洋软黏土中安装了预应力混凝土桩(PCP)而引起的不排水抗剪强度(S-u)和孔隙压力(u(2))的变化。由于安装了PCP而引起的S-u值变化是通过叶片剪切试验(VST)研究来测量的。根据预先设计的PCP构造顺序,进行压电锥渗透测试(CPTU)来检测PCP逐一驱动时的孔隙压力变化。结果表明,福州软黏土的Su-post值损失了约17%,Su-post300值为Su-pre值的1.36倍。还显示Su-pre,Su-post和Su-post300的三个拟合直线几乎平行,这有助于预测不同深度的S-u值。还基于CPTU数据提出了归一化的超孔隙压力u / sigma(v0)与径向距离与桩半径之比lg(r / R)之间的关系,可用于预测超孔隙来自不同距离的压力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号