首页> 外文期刊>International journal of ambient energy >Thermal analysis of a counterflow heat exchanger with a heat source
【24h】

Thermal analysis of a counterflow heat exchanger with a heat source

机译:带热源的逆流热交换器的热分析

获取原文
获取原文并翻译 | 示例
       

摘要

A modified analysis is presented of a counterflow plate heat exchanger that takes into account a heat source, which is assumed to be volumetrically uniform in the hot fluid. New expressions for the number of transfer units (NTU) and effectiveness of the heat exchanger are derived. These expressions are verified against the conventional effectiveness-NTU relationships in the limit of zero heat source rate. Such heat exchanger with heat source in the hot fluid is of interest in applications to ammonia-water absorption heat exchanger where a heat of absorption source term arises in the solution side. The model studies two cases based on the minimum and maximum heat capacities of the hot fluid. The results show that the number of heat transfer units and the effectiveness of the heat exchanger are not the same for both cases. The analysis is applied to an absorber heat exchanger. Effectiveness-NTU relationships are also given for a parallel flow heat exchanger with a heat source in the hot fluid.
机译:提出了一种对流板式换热器的改进分析,该换热器考虑了热源,假定该热源在热流体中的体积均匀。得出了换热单元数量(NTU)和换热器效率的新表达式。这些表达式在零热源速率的限制下针对常规有效性-NTU关系进行了验证。在热流体中具有热源的这种热交换器在氨-水吸收热交换器的应用中是令人关注的,其中吸收源项的热量在溶液侧产生。该模型基于热流体的最小和最大热容量研究了两种情况。结果表明,两种情况下的传热单元数量和热交换器的效率都不相同。该分析被应用于吸收器热交换器。对于在热流体中具有热源的平行流热交换器,也给出了效率-NTU关系。