Promoting the use of smaller diameter tube in room air conditioner is beneficial to reduce copper consumption and refrigerant charge, but may cause reduction of air conditioner performance, so a design method is needed. This paper presents a simulation-based design method for air conditioner with smaller diameter tube. The new method combines heat exchanger simulator and knowledge-based evolution method optimizer for designing air conditioner heat exchanger with smaller diameter tube. The simulation-based design method is illustrated in detail by an air conditioner of replacing 7 mm tube indoor unit heat exchanger and 9.52 mm tube outdoor unit heat exchanger with 5 mm tube. Case study shows that the cost of the designed air conditioner with 5 mm copper tube is 17.3% lower than that of the original one while the performance deviation between these two air conditioners is less than 0.7%.
机译:促进在室内空调器中使用较小直径的管有利于减少铜消耗和制冷剂充注,但可能导致空调器性能下降,因此需要一种设计方法。本文提出了一种基于仿真的管径较小的空调设计方法。该新方法结合了换热器模拟器和基于知识的演化方法优化器,设计出了管径较小的空调换热器。通过将5毫米管更换为7毫米管室内单元热交换器和9.52毫米管室外单元热交换器的空调器,详细说明了基于模拟的设计方法。案例研究表明,设计的带有5毫米铜管的空调的成本比原始空调低17.3%,而这两种空调之间的性能偏差小于0.7%。