OVERALL HEAT TRANSFER COEFFICIENT OF R407C/HC290/HC600a REFRIGERANT MIXTURE FLOWING THROUGH A FIN-AND-TUBE EVAPORATOR

机译:通过翅片管蒸发器流动的R407C / HC290 / HC600a制冷剂混合物的整体传热系数

获取原文
获取原文并翻译 | 示例
           

摘要

R22 has been used as a refrigerant in residential air-conditioners and heat pumps for many decades. Even as the Montreal protocol set the phasing out of R22 due to its ODP, many alternatives to R22 are found in published literature. The M20 refrigerant mixture is one such alternative with specific advantages. This paper presents the heat transfer characteristics of the M20 refrigerant mixture, flowing through a fin-and-tube evaporator, experimentally studied in an appliance tested in a psychrometric test facility. The experimental setup consisted of a window air-conditioner fixed in a psychrometric room with instruments to measure the temperatures/ pressures of the refrigerant and mass flow rate of the refrigerant as well as air. The experiment was carried out in accordance with the Bureau of Indian Standards (BIS) and American Society of Heating Refrigerating Air-Conditioning Engineers (ASHRAE) test conditions. M20 being considered as an alternative for R22, the overall heat transfer coefficient of the M20 refrigerant mixture has been evaluated, and compared with that of R22. It can be observed that the heat transfer coefficient of R22 is better than that of the M20 refrigerant mixture, for the prevailing flow conditions in the evaporator. The reduction in the overall heat transfer coefficient of the M20 refrigerant mixture as compared to R22, ranges from 7.3% to 20.7%.
机译:R22在住宅空调和热泵中已用作制冷剂数十年。即使蒙特利尔协议由于其ODP决定逐步淘汰R22,在已发表的文献中也可以找到R22的许多替代方案。 M20制冷剂混合物是一种具有特殊优势的替代方案。本文介绍了流经翅片管蒸发器的M20制冷剂混合物的传热特性,该实验是在干湿法测试设备中测试过的设备中进行的。实验装置由安装在干湿室中的窗式空调组成,该窗式空调装有用于测量制冷剂的温度/压力,制冷剂以及空气的质量流量的仪器。该实验是根据印度标准局(BIS)和美国加热制冷空调工程师协会(ASHRAE)的测试条件进行的。 M20被认为是R22的替代品,已经评估了M20制冷剂混合物的总传热系数,并将其与R22进行了比较。可以观察到,对于蒸发器中的主要流动条件,R22的传热系数优于M20制冷剂混合物的传热系数。与R22相比,M20制冷剂混合物的总传热系数降低了7.3%至20.7%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号