Determining the on-field heating capacity and coefficient of performance (COP) of residential air-to-air heat pumps (HPs) is problematic, given that measuring accurately the enthalpy and, specifically, the mass flow rate of air is challenging. This paper validates a promising on-field performance measurement method for HPs with an internal heat exchanger (IHX) as vapor injection system using experimental data obtained from air-to-water heat pump prototype in several operating conditions. The method is based on refrigerant fluid measurements and component energy/mass balances. Nonintrusive sensors, such as surface temperature sensors, are used to estimate pressure and refrigerant mass flow rate in different types of heat pump systems, including air-to-air. Obtained results compared with intrusively measured reference values in steady-state conditions are in good agreement, suggesting that a comprehensive performance analysis can be conducted in already-installed high efficiency residential IHX air-to-water HPs, as well as internal heat exchanger air-to-air HPs.
机译:考虑到准确测量焓,特别是空气的质量流量,确定住宅空气对空气热泵(HPs)的现场供热能力和性能系数(COP)是有问题的。本文使用从空气-水热泵原型在几种运行条件下获得的实验数据,验证了一种以内部热交换器(IHX)作为蒸汽喷射系统的高压泵的现场性能测量方法。该方法基于制冷剂流体测量值和组分能量/质量平衡。非侵入式传感器(例如表面温度传感器)用于估算不同类型的热泵系统(包括空对空)中的压力和制冷剂质量流量。与在稳态条件下侵入式测量的参考值相比,获得的结果吻合良好,这表明可以对已经安装的高效民用IHX空气-水HP和内部热交换器空气进行综合性能分析。空中HP。

著录项

  • 来源
    《International journal of air-conditioning and refrigeration》 |2016年第2期|1650011.1-1650011.9|共9页
  • 作者单位

    Centre for Energy efficiency of Systems (CES) MINES ParisTech, PSL Research University 60 Boulevard Saint-Michel, Paris 75006, France ,EDF R&D, Energy in Buildings and Territories Department (ENERBAT) Avenue des Renardieres, Ecuelles 77250, France;

    Centre for Energy efficiency of Systems (CES) MINES ParisTech, PSL Research University 60 Boulevard Saint-Michel, Paris 75006, France;

    EDF R&D, Energy in Buildings and Territories Department (ENERBAT) Avenue des Renardieres, Ecuelles 77250, France;

    Centre for Energy efficiency of Systems (CES) MINES ParisTech, PSL Research University 60 Boulevard Saint-Michel, Paris 75006, France;

    EDF R&D, Energy in Buildings and Territories Department (ENERBAT) Avenue des Renardieres, Ecuelles 77250, France;

    Centre for Energy efficiency of Systems (CES) MINES ParisTech, PSL Research University 60 Boulevard Saint-Michel, Paris 75006, France;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Heat pump; coefficient of performance; internal heat exchanger; refrigerant measurements;

    机译:热泵;性能系数;内部热交换器制冷剂测量;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号