首页> 外文期刊>International Communications in Heat and Mass Transfer >A model to predict the effect of surface wettability on critical heat flux
【24h】

A model to predict the effect of surface wettability on critical heat flux

机译:预测表面润湿性对临界热通量影响的模型

获取原文
获取原文并翻译 | 示例
           

摘要

Critical heat flux (CHF) in pool boiling experiments corresponds to the heat flux at which a vapor film is formed on the heated surface resulting from the replacement of liquid by vapor adjacent to this surface. Poor thermal conductivity of vapor can severely deteriorate heat transfer. It is important that systems operate below this limit which is a strong limitation to heat transfer due to the huge increase of the thermal resistance near the wall. The concept of macro- and micro-contact angles has been introduced in a previous paper (Phan et al., 2010 [28]) to describe the bubble growth processes. In this paper, an explicit relation between the bubble departure diameter and the contact angle has been presented. Based on these results, we propose a model of critical heat flux, taking into account the effects of the wettability of the fluid, whose property is known to strongly influence boiling heat transfer. A new correlation for CHF, dependent on the contact angle, is proposed. It is found in fair agreement with existing experimental results concerning subcooled boiling to describe the variation of CHF with wettability.
机译:池沸腾实验中的临界热通量(CHF)对应于这样的热通量,在该热通量下,受热表面上的汽化膜是由与该表面相邻的蒸汽替代液体而产生的。蒸气的导热性差会严重损害传热。重要的是,系统必须在此极限以下运行,这是由于壁附近热阻的大幅增加而对传热的强烈限制。在先前的论文(Phan等人,2010 [28])中已经引入了宏观和微观接触角的概念来描述气泡的生长过程。在本文中,提出了气泡离开直径和接触角之间的明确关系。基于这些结果,我们提出了一种临界热通量模型,其中考虑了流体的可润湿性的影响,已知该流体的性质会强烈影响沸腾传热。提出了一种新的CHF相关性,具体取决于接触角。发现与关于过冷沸腾的现有实验结果完全吻合,以描述CHF随润湿性的变化。

著录项

  • 来源
  • 作者单位

    UJF-Grenoble 1/Grenoble-INP/CNRS, LEGI UMR 5519, Grenoble, F-38041, France,CEA, UTEN/DTS/LETH, 17 rue des Martyrs, 38054 Grenoble cedex 9, France;

    UJF-Grenoble 1/Grenoble-INP/CNRS, LEGI UMR 5519, Grenoble, F-38041, France,CEA, UTEN/DTS/LETH, 17 rue des Martyrs, 38054 Grenoble cedex 9, France;

    UJF-Grenoble 1/Grenoble-INP/CNRS, LEGI UMR 5519, Grenoble, F-38041, France,CEA, UTEN/DTS/LETH, 17 rue des Martyrs, 38054 Grenoble cedex 9, France;

    UJF-Grenoble 1/Grenoble-INP/CNRS, LEGI UMR 5519, Grenoble, F-38041, France,CEA, UTEN/DTS/LETH, 17 rue des Martyrs, 38054 Grenoble cedex 9, France;

    CEA, UTEN/DTS/LETH, 17 rue des Martyrs, 38054 Grenoble cedex 9, France;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    pool boiling; critical heat flux; contact angle; wettability;

    机译:池沸腾;临界热通量;接触角润湿性;