...
首页> 外文期刊>International Communications in Heat and Mass Transfer >Coupling management optimization of temperature and thermal stress inside 3D-IC with multi-cores and various power density
【24h】

Coupling management optimization of temperature and thermal stress inside 3D-IC with multi-cores and various power density

机译:多芯和各种功率密度3D-IC内温度和热应力的耦合管理优化

获取原文
获取原文并翻译 | 示例
           

摘要

A three-dimensional integrated circuit (3D-IC) is representative of technologies that have achieved the "beyond Moore's Law" concept. However, a 3D-IC suffers from the thornier problems of local overheating and thermal stress concentration as a result of its higher integration. Herein, a 3D-IC model with a real microprocessor structure to explore the temperature and thermal stress distributions under a closed microchannel liquid cooling condition. Finally, the effects of the structural parameters, flow direction of the cooling water, and core area overclocking on the maximum temperature, thermal stress distribution, and total pressure drop inside the 3D-IC model were investigated. The numerical results indicated that a mixed arrangement of micro-pin fins in the bottom microchannel and in-line arrangement in the upper microchannel was beneficial for balancing the maximum temperature and pressure drop. Moreover, the maximum thermal stress decreased by 34% after parallel flow and an optimized upper microchannel structure were adopted in the 3D-IC. Furthermore, the reliability of the chip with the optimized structure was governed by the thermal failure risk instead of thermal stress. Therefore, to balance the reliability and pumping power consumption of chips, maintaining the maximum temperature at 333 K could be a reference for 3D-IC coupling management.
机译:三维集成电路(3D-IC)代表了实现了“超越摩尔法”概念的技术。然而,由于其更高的整合,3D-IC遭受局部过热和热应力集中的棘手问题。这里,具有真实微处理器结构的3D-IC模型,以探讨闭合微通道液体冷却条件下的温度和热应力分布。最后,研究了结构参数,冷却水的流动方向和超频在最大温度,热应力分布和3D IC模型内的总压降的效果。数值结果表明,上部微通道中的微销翅片和上部微通道中的在线布置的混合布置有利于平衡最大温度和压力下降。此外,在3D-IC中采用了平行流量和优化的上微通道结构后,最大热应力降低了34%。此外,具有优化结构的芯片的可靠性受到热故障风险而不是热应力的控制。因此,为了平衡芯片的可靠性和泵送功耗,保持333k的最大温度可以是3D-IC耦合管理的参考。

著录项

  • 来源
    《International Communications in Heat and Mass Transfer》 |2021年第1期|105021.1-105021.10|共10页
  • 作者单位

    Department of Energy & Power Engineering China University of Petroleum (East China) Qingdao Shandong 266580 China;

    Department of Energy & Power Engineering China University of Petroleum (East China) Qingdao Shandong 266580 China;

    Department of Energy & Power Engineering China University of Petroleum (East China) Qingdao Shandong 266580 China Institute of New Energy China University of Petroleum (East China) Qingdao Shandong 266580 China;

    Institute of New Energy China University of Petroleum (East China) Qingdao Shandong 266580 China;

    Department of Energy & Power Engineering China University of Petroleum (East China) Qingdao Shandong 266580 China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Coupling management; 3D-IC; Interlayer microchannel; Thermal stress; Overclocking;

    机译:耦合管理;3D-IC;中间微通道;热应力;超频;
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号