A system to measure the noise temperature (NT) of noise sources is implemented in the frequency range of 18–26.5 GHz for the case where noise sources commercially available have only one nominal NT, e.g., 9500 K being equivalent to 15-dB excess noise ratio. For the Y-factor method, two noise sources, i.e., a noise source and another with a radio-frequency attenuator, serve as the standard noise sources. The noise power output of the noise sources are measured using a commercial noise figure measurement instrument. Measurement results are presented, and its uncertainty has been evaluated to be 0.23–0.25 dB $(k = 2)$ .
机译:在市售噪声源只有一个标称NT的情况下(例如9500 K等效于15 dB过量噪声),在18-26.5 GHz频率范围内实施了一种测量噪声源噪声温度(NT)的系统比。对于Y因子方法,两个噪声源,即一个噪声源和另一个具有射频衰减器的噪声源,用作标准噪声源。噪声源的噪声功率输出使用商用噪声系数测量仪器进行测量。给出了测量结果,其不确定度估计为0.23–0.25 dB $(k = 2)$。