首页> 外文期刊>IEEE Transactions on Instrumentation and Measurement >Automated calibration methods for a high-voltage Park divider
【24h】

Automated calibration methods for a high-voltage Park divider

机译:高压Park分压器的自动校准方法

获取原文
获取原文并翻译 | 示例

摘要

Two new methods of calibrating the 1/10 voltage ratio of a 100-kV Park divider, which has been provided with a set of tenths ratio taps is described. The proposed methods make PC-controlled measurements based on (1) Wheatstone bridge circuits configurable entirely with the resistive sections of the tapped divider, and (2) a digital conductance comparator, respectively. The 1/10 ratio measurements made by these quite different methods were found to be consistent to 3 ppm of the ratio. The conductance comparison method, with an assessed standard uncertainty of 2 ppm, determined precisely the effect of self-heating on the measured ratio, minute-by-minute after the rated input was applied. Subdividing the established 1/10 ratio to 1/100 and 1/10/sup 5/ of input, however, is based on more conventional methods. These subdivided ratios have been given a standard uncertainty not exceeding 6 ppm in the absence of corona discharge.
机译:描述了两种新的校准100 kV Park分压器1/10电压比的方法,该方法配有十分之一的比例抽头。所提出的方法基于(1)惠斯通电桥电路完全由抽头分压器的电阻部分构成,以及(2)数字电导比较器,使PC控制的测量成为可能。发现通过这些完全不同的方法进行的1/10比率测量值与比率的3 ppm一致。电导率比较方法具有2 ppm的估计标准不确定性,可在施加额定输入后的每一分钟内,精确地确定自热对测量比率的影响。但是,将建立的1/10比率细分为输入的1/100和1/10 / sup 5 /是基于更常规的方法。在没有电晕放电的情况下,这些细分比率的标准不确定度不超过6 ppm。