首页> 外文期刊>Inorganic materials: applied research >On the Choice of the Architecture of Osteoconductive Bioceramic Implants
【24h】

On the Choice of the Architecture of Osteoconductive Bioceramic Implants

机译:骨传导性生物陶瓷植入物的结构选择

获取原文
获取原文并翻译 | 示例
       

摘要

An a priori approach for the analysis of the architecture of osteoconductive bioceramic implants has been proposed. The most permeable products have been achieved in the case of the Kelvin architecture and the gyroid. The promising implant architecture is chosen to be the Kelvin model with a porosity of 70% and the pore sizes of 750 μm. The permeability of this architecture calculated to be 987 darcy for water approaches the value of trabecular bone tissue. It is found that the most rigid model among the architectures studied is the model with diamond architecture, while the most compliant are the Kelvin model and gyroid.
机译:已经提出了用于分析骨传导性生物陶瓷植入物的结构的先验方法。在开尔文(Kelvin)建筑和陀螺仪的情况下,获得了最具渗透性的产品。选择有前途的植入物体系结构作为开尔文模型,其孔隙率为70%,孔径为750μm。计算得出的该结构的渗透性为987达西水,接近小梁骨组织的价值。结果发现,在所研究的架构中,最严格的模型是具有钻石架构的模型,而最兼容的是Kelvin模型和gyroid。