When to Replace Aging Transformers: Guidelines to Replace Older Transformers Before Failure

机译:何时更换老化的变压器:故障前更换旧变压器的准则

获取原文
获取原文并翻译 | 示例
       

摘要

Transformers play critical roles in delivering power to distribution equipment for homes, commercial establishments, and industrial facilities. The sudden failure of a transformer can cause serious repercussions, leading to loss of power for a few minutes to hours. There are cases where an outage can last for weeks because of the system configuration, such as a simple radial system or the transformer was the single-point failure. In industrial complexes, an outage lasting for a few minutes could lead to loss opportunities as well as millions of dollars in lost production and start-up costs. Many older transformers have been in operation for more than 80 years without failure or major problems. There have been recent failures of units producing fires and explosions, resulting in the release of toxic and combustible gases as well as smoke into the atmosphere; Also, the Occupational Safety and Health Administration (OSHA) has levied fines because of the type of incidents. Many transformers in the petrochemical industry now fall under OSHA 1910.119 [15], mechanical integrity regulations, due to the probability of catastrophic failure during power loss, resulting in the release of highly hazardous chemicals. Transformer tanks containing more than 10,000 lb of aggregates sometime fall under the 1910.119 as well as 1910.269 regulations. Mineral oil in transformers is used as a media for cooling and insulating parts within close proximity. Mineral oil has a National Fire Protection Association (NFPA) flammability rating of one, indicating it is slightly flammable with a health rating of one, indicating a slight health hazard. During fault conditions, however, mineral oil can be hazardous to your health and the environment.
机译:变压器在为家庭,商业机构和工业设施的配电设备供电中扮演着至关重要的角色。变压器的突然故障会引起严重的后果,导致几分钟到几小时的断电。在某些情况下,由于系统配置的原因,停电可能会持续数周,例如简单的径向系统或变压器是单点故障。在工业园区中,持续数分钟的停机可能导致损失机会以及数百万美元的生产和启动成本损失。许多老式变压器已经运行了80多年,没有出现故障或重大问题。最近发生火灾和爆炸的单位发生了故障,导致有毒和可燃气体以及烟雾释放到大气中;此外,由于事故类型,美国职业安全与健康管理局(OSHA)已罚款。由于停电期间发生灾难性故障的可能性,导致释放出高危化学物质,石化行业中的许多变压器现在都符合OSHA 1910.119 [15]的机械完整性规定。有时,包含超过10,000 lb的骨料的变压器储罐必须符合1910.119和1910.269的规定。变压器中的矿物油用作介质,用于冷却和绝缘附近的零件。矿物油的国家防火协会(NFPA)可燃性等级为1,表明它是轻度易燃的,健康等级为1,表明对健康有轻微危害。但是,在故障情况下,矿物油可能会危害您的健康和环境。

著录项

  • 来源
    《Industry Applications Magazine, IEEE》 |2012年第5期|p.46-56|共11页
  • 作者单位

    Capital Projects/Reliability Dept., Chevron Phillips Chemical Co., Old Ocean, Texas 77463 USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号