Frequency relays are often applied on power systems either to protect generation equipment or provide load shedding capabilities. Accurate setting and operation of these relays is essential in the proper coordination of the power system equipment. Dynamic testing provides a method of assuring the proper operation of frequency relays. Along with this testing is a myriad of complexities and confusion. Dynamic tests are not always as straightforward as one might think, especially when the results are not as anticipated. The methods of testing, type of test equipment used, and the specific relay measuring techniques all play a significant role in the dynamic testing results. This paper discusses the intricacies of dynamic frequency testing along with the differences between test equipment and frequency relays and how these differences affect the testing results. A sampling of four frequency relays was tested (three solid-state devices and one electromechanical), each using four different test sets. Results of each are discussed.
机译:频率继电器通常应用于电力系统,以保护发电设备或提供减载能力。这些继电器的准确设置和操作对于电力系统设备的正确协调至关重要。动态测试提供了一种确保频率继电器正常运行的方法。伴随这项测试的是无数的复杂性和混乱。动态测试并不总是像人们想像的那样简单明了,尤其是在结果未达到预期的情况下。测试方法,所用测试设备的类型以及特定的继电器测量技术在动态测试结果中均起着重要作用。本文讨论了动态频率测试的复杂性,以及测试设备和频率继电器之间的差异以及这些差异如何影响测试结果。测试了四个频率继电器(三个固态设备和一个机电)的采样,每个都使用四个不同的测试集。讨论每个结果。