首页> 外文期刊>IEEE Transactions on Industry Applications >Feedforward Loss Control of Three-Level Active NPC Converters
【24h】

Feedforward Loss Control of Three-Level Active NPC Converters

机译:三电平有源NPC转换器的前馈损耗控制

获取原文
获取原文并翻译 | 示例
           

摘要

The three-level neutral-point-clamped voltage-source converter (NPC VSC) is widely used in high-power medium-voltage (MV) applications. To overcome its major drawback—the unequal loss distribution among the semiconductors—the use of active NPC (ANPC) switches was previously proposed. In this paper, a simple feedforward loss-control scheme for the ANPC converter is presented. The principle of operation of the ANPC VSC is experimentally verified for the first time. Electrical measurements on a low-voltage test bench prove the proper function of the ANPC converter. Infrared junction temperature measurements confirm the improved loss distribution using the new loss-control scheme. Finally, the authors demonstrate the superior performance of the loss-controlled ANPC converter in various MV applications.
机译:三电平中性点钳位电压源转换器(NPC VSC)广泛用于大功率中压(MV)应用。为了克服其主要缺点-半导体之间的损耗分布不均-先前曾提出使用有源NPC(ANPC)开关。本文提出了一种简单的ANPC转换器前馈损耗控制方案。 ANPC VSC的工作原理首次通过实验验证。低压测试台上的电气测量证明了ANPC转换器的正常功能。红外结温测量结果证实了使用新的损耗控制方案改善的损耗分布。最后,作者展示了在各种MV应用中损耗控制的ANPC转换器的优越性能。