Ensuring correct setting and installation of a transformer differential relay is critical. A transformer differential relay must detect internal faults, damaging overloads, and through-fault currents while remaining secure against misoperation. The ability to use wye-connected current transformers with microprocessor-based relays has simplified installations, and these relays provide better commissioning tools than those available with traditional relays. However, installations and commissioning remain complicated. Installation and settings errors continue to be widespread, implying a need for more rigorous commissioning tests. Even with greater commissioning effort, occasional wiring problems develop over time, and these can best be resolved through analysis of relay event-report data. In the interest of reducing transformer differential misoperations, we share in this technical paper practical lessons we have learned through experience with commissioning and relay event-report analysis.
机译:确保正确设置和安装变压器差动继电器至关重要。变压器差动继电器必须检测内部故障,破坏性过载和直通故障电流,同时还要确保避免误操作。将星形连接的电流互感器与基于微处理器的继电器一起使用的能力简化了安装,并且与传统继电器相比,这些继电器提供了更好的调试工具。但是,安装和调试仍然很复杂。安装和设置错误仍然很普遍,这意味着需要进行更严格的调试测试。即使投入更多的调试精力,偶尔的接线问题也会随着时间而发展,这些问题可以通过分析继电器事件报告数据来最好地解决。为了减少变压器的差动误操作,我们在本技术文件中分享了通过调试和继电器事件报告分析的经验教训。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号