In this paper, we present the conjugate heat transfer analysis in a 167-kVA dry-type transformer using the parallel version of the computational fluid dynamics code Fluent 6.0. The renormalization group kappa-epsiv model is proposed to compute the turbulent aspect of the convective airflow inside the transformer metal tank for Air Natural/Air Natural cooling conditions. An experimental approach was used to assess Joule losses in the low-/high-voltage windings and eddy-current losses in the magnetic core. The resulting mathematical model was solved using 14 compute nodes on a distributed machine.
机译:在本文中,我们使用计算流体力学代码Fluent 6.0的并行版本介绍了167-kVA干式变压器中的共轭传热分析。提出了重归一化组kappa-epsiv模型,以计算自然空气/自然空气冷却条件下变压器金属罐内对流气流的湍流方面。实验方法用于评估低压/高压绕组中的焦耳损耗和磁芯中的涡流损耗。使用分布式计算机上的14个计算节点求解了所得的数学模型。