The doubly fed induction generator (DFIG) is one of the main technologies at variable speed power generation systems. Reliability and efficiency are key factors to realize the maximum energy output of the renewable resources. Detecting generator faults enables the reduction of risk for unexpected outages and thus high economic losses. Stator winding insulation faults count to one of the most frequent failures in electric machines. Common fault detection methods are based on several additional sensors and hardware what makes the system complex, expensive and also fault-prone. In this paper, a method is proposed and investigated to detect stator winding faults based only on measured signals available from inverter build-in sensors. By rotor-side inverter switching the generator is excited by transient voltage pulses and the current response provides the possibility to extract a fault indicator through a specific signal processing. Measurements on a DFIG test stand prove the methods applicability and accuracy.
机译:双馈感应发电机(DFIG)是变速发电系统中的主要技术之一。可靠性和效率是实现可再生资源最大能量输出的关键因素。检测发电机故障可以降低意外停机的风险,从而减少高额的经济损失。定子绕组绝缘故障是电机中最常见的故障之一。常见的故障检测方法基于几种附加的传感器和硬件,这使系统变得复杂,昂贵且容易发生故障。本文提出并研究了一种仅基于逆变器内置传感器提供的测量信号来检测定子绕组故障的方法。通过转子侧逆变器切换,发电机会被瞬态电压脉冲激励,电流响应提供了通过特定信号处理提取故障指示器的可能性。在DFIG测试台上进行的测量证明了该方法的适用性和准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号