首页> 外文期刊>Industry Applications, IEEE Transactions on >Performance of Shipboard Medium-Voltage DC System of Various Grounding Modes Under Monopole Ground Fault
【24h】

Performance of Shipboard Medium-Voltage DC System of Various Grounding Modes Under Monopole Ground Fault

机译:单极接地故障下各种接地方式的舰载中压直流系统的性能

获取原文
获取原文并翻译 | 示例
           

摘要

This paper compares different grounding modes of a shipboard medium-voltage dc (MVDC) system such as ungrounded, solidly grounded, grounded with resistors, and grounded with resistors in parallel. Based on a typical shipboard MVDC system under different grounding modes, the transient short-circuit current and overvoltage under a monopole ground fault condition are calculated with PSCAD/EMTDC. The impact of the grounding resistance on the fault feature of the system is also studied. According to the comparative analysis and simulation results, a suitable grounding mode and the grounding resistance are proposed. The influences of load conditions, capacitance of loads, capacitance of the transmission cables, resistance between line and ground at the fault point, and fault position on the overvoltage are considered. Finally, a system protection scheme consisting of grounding mode selection, capacitor, arrester, and conjugate mirror filter has been developed.
机译:本文比较了舰船中压直流(MVDC)系统的不同接地方式,例如不接地,牢固接地,电阻接地以及并联电阻接地。基于典型的舰船在不同接地模式下的MVDC系统,利用PSCAD / EMTDC计算单极接地故障条件下的瞬态短路电流和过电压。还研究了接地电阻对系统故障特征的影响。根据比较分析和仿真结果,提出了合适的接地方式和接地电阻。考虑负载条件,负载电容,传输电缆的电容,故障点的线路与地面之间的电阻以及故障位置对过电压的影响。最后,开发了一种由接地模式选择,电容器,避雷器和共轭镜滤波器组成的系统保护方案。