In industrial applications where both dc and ac adjustable speed drives (ASDs) are used, high levels of harmonic voltage and current distortions are produced. For instance, in the oil and gas industry, including land and offshore drilling rigs and ships, deep notches in the voltage waveform exist due to silicon-controlled rectifier or thyristor (SCR's) operation in the mud pump dc drives. With voltage distortion often exceeding 20%, equipment associated with the drilling operation can experience erratic operation and equipment damage. Even though the notch phenomenon is well understood, the failure mode of ac ASDs has not been analyzed in published literatures. This paper provides the background of the typical power distribution installation in such an application, and analyzes the voltage notches in ac/dc converters and the problems that they create; more significantly, presents the ac ASD components failure mechanisms and proposes a cost effective solution without introducing expensive harmonic filters. The theoretical foundation and analytical derivation that are used to calculate notch depth, width, and frequency resonance excitation interacting with ac ASD's electromagnetic interference filter will be discussed. Variation factors influencing the harmonic characteristics including SCR firing angle, generator, and cable impedance, ASD's input ac inductors or dc chokes are quantitatively evaluated. It will be demonstrated that ASDs with dc chokes are less sensitive to cause resonances through system harmonics interaction, possibly eliminating the need to install expensive and large passive filters. Theoretical and simulation models are validated through an experimental setup of a 15 kW 480-V ASD system.
机译:在同时使用直流和交流可调速驱动器(ASD)的工业应用中,会产生高水平的谐波电压和电流失真。例如,在石油和天然气工业中,包括陆地和海上钻井平台和船舶,由于泥浆泵直流驱动器中的硅控整流器或晶闸管(SCR)操作,电压波形中存在深陷波。由于电压畸变通常超过20%,与钻井作业相关的设备可能会遇到不稳定的操作和设备损坏。即使已经很好地理解了缺口现象,但交流ASD的故障模式尚未在已发表的文献中进行分析。本文提供了此类应用中典型配电设备的背景,并分析了AC / DC转换器中的电压陷波以及它们产生的问题。更重要的是,提出了交流ASD组件的故障机制,并提出了一种经济有效的解决方案,而无需引入昂贵的谐波滤波器。将讨论用于计算与交流ASD的电磁干扰滤波器相互作用的陷波深度,宽度和频率谐振激励的理论基础和解析推导。影响谐波特性的变化因素包括SCR触发角,发电机和电缆阻抗,对ASD的输入交流电感器或直流电抗器进行了定量评估。将证明具有直流电抗器的ASD对系统谐波相互作用引起的共振不太敏感,从而可能无需安装昂贵的大型无源滤波器。理论模型和仿真模型通过15 kW 480-V ASD系统的实验设置进行了验证。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号