首页> 外文期刊>Industry Applications, IEEE Transactions on >Fault Current Detection and Dangerous Voltages in DC Urban Rail Traction Systems
【24h】

Fault Current Detection and Dangerous Voltages in DC Urban Rail Traction Systems

机译:直流城市轨道交通系统中的故障电流检测和危险电压

获取原文
获取原文并翻译 | 示例
       

摘要

In this paper, the electrical safety of dc urban traction systems is analyzed, with particular focus on fault current detection and on dangerous voltages which could arise in case of fault. For the discussion, the tram network of Turin, Italy, is used as a case study. First, the structure of the dc traction power supply is described, analyzing in detail the different components; then, the safety of the system is analyzed, examining possible types of fault. In particular, ground faults inside the substation and ground faults along the line are analyzed in detail. Fault currents and dangerous voltages are calculated, thanks to a simplified steady-state circuital model of the traction system. Finally, the consequent risks for the people are examined and some conclusions and possible solutions are presented.
机译:在本文中,分析了城市直流牵引系统的电气安全性,特别侧重于故障电流检测和故障情况下可能产生的危险电压。在讨论中,以意大利都灵的电车网络为例。首先,描述直流牵引电源的结构,详细分析不同的组件;然后,分析系统的安全性,检查可能的故障类型。特别是,详细分析了变电站内部的接地故障和沿线的接地故障。通过牵引系统的简化稳态电路模型,可以计算出故障电流和危险电压。最后,研究了对人民带来的风险,并提出了一些结论和可能的解决方案。