Motor current signature analysis (MCSA) based detection of rotor cage faults (RFs) in medium-high voltage induction motors has become common in the field due to its low-cost remote monitoring capability. However, low-frequency load oscillations (LOs) in applications that employ speed reduction couplings can induce frequency components in the vicinity of that of RFs. It has been reported that false-positive or -negative RF indications can be produced with the MCSA, if the frequency components produced by RF and LO overlap. There, recently, have been studies on discriminating RF and LO; however, the case where two harmonic components overlap at the same frequency, which is the most difficult and serious case, has not been investigated. In this paper, a spectrum analysis of instantaneous active and reactive power is applied, and it is shown that RF and LO can be separated for the case where the MCSA fails due to the overlap in the two spectral components. An experimental study performed on a 380 V motor with a speed reduction gear shows that RF and LO can be reliably detected and separated for avoiding false RF indications.
机译:在中高压感应电动机中,基于电动机电流特征分析(MCSA)的转子笼故障(RF)的检测由于其低成本的远程监控功能而在该领域变得很普遍。但是,在采用减速耦合的应用中,低频负载振荡(LO)可能会在RF频率附近感应出频率分量。据报道,如果由RF和LO产生的频率分量重叠,则可以用MCSA产生假阳性或阴性RF指示。最近,有关于区分RF和LO的研究。然而,尚未研究两个谐波分量以相同频率重叠的情况,这是最困难和最严重的情况。在本文中,对瞬时有功功率和无功功率进行了频谱分析,结果表明,当MCSA由于两个频谱分量重叠而失效时,RF和LO可以分开。在带有减速齿轮的380 V电动机上进行的实验研究表明,可以可靠地检测和分离RF和LO,以避免出现错误的RF指示。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号