首页> 外文期刊>IEEE Transactions on Industry Applications >A Novel Method for Estimating the High Frequency Incremental DQ-Axis and Cross-Coupling Inductances in Interior Permanent Magnet Synchronous Machines
【24h】

A Novel Method for Estimating the High Frequency Incremental DQ-Axis and Cross-Coupling Inductances in Interior Permanent Magnet Synchronous Machines

机译:一种估计内部永磁同步机中高频增量DQ轴和交叉耦合电感的新方法

获取原文
获取原文并翻译 | 示例
       

摘要

This article proposes a novel method for estimating the high-frequency (HF) incremental dq-axis and cross-coupling inductances of interior permanent magnet synchronous machines based on both the HF rotating and pulsating voltage injection techniques. It mainly includes three HF voltage injection stages, i.e., a HF rotating voltage injection in the stationary reference frame, and a pulsating voltage injection in the d-axis and a pulsating voltage injection in the q-axis of the synchronous rotating reference frame. Compared with conventional estimation methods which either use only rotating voltage injection, or use only pulsating voltage injections in the dq-axes, the proposed method neither requires the closed-loop position estimator to obtain the offset angle caused by the cross-coupling effect nor is sensitive to the delay effects caused by digital filters and voltage synthesis. The estimated results obtained by the proposed method show a good agreement with those by finite element analysis and are also compared with those obtained by the conventional methods.
机译:本文提出了一种基于HF旋转和脉动电压注入技术的内部永磁同步机的高频(HF)增量DQ轴和交叉耦合电感的新方法。它主要包括三个HF电压注入级,即静止参考帧中的HF旋转电压注入,以及在D轴上的脉动电压注入和同步旋转参考框架的Q轴中的脉动电压注入。与仅使用旋转电压注入的传统估计方法相比,或仅使用DQ轴中的脉动电压注射,所提出的方法既不需要闭环位置估计器以获得由交叉耦合效果引起的偏移角也不是对数字滤波器和电压合成引起的延迟效应敏感。通过该方法获得的估计结果与有限元分析的估计结果显示出良好的协议,也与通过常规方法获得的那些进行比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号